PRBD201702910
There are no deposits or bonds for this permit application.
Inspection | Outcome | Requested | Scheduled | Date Complete |
---|---|---|---|---|
Framing Inspection | Partial Pass | 7/25/2017 (8:00 - 10:00) | 7/25/2017 | 07/25/2017 |
Corrections:
Miscellaneous/Other
Outstanding
07/25/2017
Walls - interior and exterior- OK. A) exterior wall insulation inspection required to deck, see North and south end of space. B) Need to Confirm restrooms changing station location for single use restrooms.
|
||||
Insulation Inspection | Passed | 08/15/2017 | ||
Exterior wall block foundation. A. R-13 interior framing fiberglass to roof deck. | ||||
Corrections:
Miscellaneous/Other
Outstanding
08/15/2017
Insulation. Interior framing insulation over block foundation exterior walls to deck. R-13 fiberglass.
|
||||
Framing Inspection | Passed w/ Conditions | 8/17/2017 (8:00 - 10:00) | 8/17/2017 | 08/17/2017 |
Corrections:
Miscellaneous/Other
Outstanding
08/17/2017
Framing progress interior inspection - approved. OK to proceed. A) Provide for rough in inspection for fire sprinkler, and be sure to provide for exterior electrical illumination of exits on emergency lighting back up for loss of power.
|
||||
Fire Inspection Final | Partial Pass | 9/27/2017 (8:00 - 10:00) | 9/27/2017 | 09/27/2017 |
Corrections:
Ceiling tile installation not completed.
Outstanding
09/27/2017
Ceiling tile installation not completed.
|
||||
Address signage
Outstanding
09/27/2017
Address signage
|
||||
Miscellaneous/Other
Outstanding
09/27/2017
Must test roof top units for duct smoke activation and report to panel.
|
||||
Provide emergency lighting.
Outstanding
09/27/2017
Provide emergency lighting test.
|
||||
Miscellaneous/Other
Outstanding
09/27/2017
Roof top screening, per planning. Planning must determine roof top screening.
|
||||
Building Final Inspection | Not Ready | 9/27/2017 (8:00 - 10:00) | 9/27/2017 | 09/27/2017 |
Corrections:
Miscellaneous/Other
Carried Forward
09/27/2017
Temp CO - A. FINAL for fire, electrical, low voltage, HVAC. Need ceiling in rear of store padded out with plenum rated insulation 25/50 . Store front and rear address numbers.
B. Roof top screening per city Planning Division.
|
||||
Fire Inspection Final | Issue TCO | 10/19/2017 (12:30 - 2:30) | 10/19/2017 | 10/19/2017 |
Corrections:
Provide emergency lighting.
Carried Forward
10/19/2017
Provide emergency lighting.
|
||||
Building Final Inspection | Issue TCO | 10/19/2017 (12:30 - 2:30) | 10/19/2017 | 10/19/2017 |
Corrections:
Miscellaneous/Other
Carried Forward
10/19/2017
Temp CO - A. FINAL for fire, electrical, low voltage, HVAC. Need ceiling in rear of store padded out with plenum rated insulation 25/50 . Store front and rear address numbers.
B. Roof top screening per city Planning Division.
|
||||
Miscellaneous/Other
Carried Forward
10/19/2017
Temp. CO - 20 DAYS. A. Paint roof top units, per city planning, and confirm emergency lighting levels in early am, front door to be operational, finals for fire, HVAC, plumbing, low voltage fire alarm, and planning. Address numbers FOR front and rear entrances. Complete stocking of store 100 percent.
|
||||
Fire Inspection Final | Passed | 02/09/2018 | ||
Corrections:
Provide emergency lighting.
Outstanding
10/19/2017
Provide emergency lighting.
|
||||
Building Final Inspection | Passed | 03/09/2018 | ||
Corrections:
Miscellaneous/Other
Outstanding
10/19/2017
Temp CO - A. FINAL for fire, electrical, low voltage, HVAC. Need ceiling in rear of store padded out with plenum rated insulation 25/50 . Store front and rear address numbers.
B. Roof top screening per city Planning Division.
|
||||
Miscellaneous/Other
Outstanding
10/19/2017
Temp. CO - 20 DAYS. A. Paint roof top units, per city planning, and confirm emergency lighting levels in early am, front door to be operational, finals for fire, HVAC, plumbing, low voltage fire alarm, and planning. Address numbers FOR front and rear entrances. Complete stocking of store 100 percent.
|
||||
Miscellaneous/Other
Comment Only
03/09/2018
Final - A. Additional emergency lighting added under separate electrical permit. Approved.
B. Roof top HVAC UNITS PAINTED APPROVED BY CITY PLANNING TO ISSUE FINAL. C. NOTE - FIRE SPRINKLER PERMIT IS STILL OPEN, CONTACT THEM FOR FINAL APPROVAL ALSO PER BUILDING INSPECTOR BRIAN POST.
|
||||
Miscellaneous/Other
Resolved
03/09/2018
Final - A. FINAL FIRE HAD BEEN APPROVED PRIOR TO FINAL BUILDING TODAY. THANK YOU ALL.
|