PRBD201707731
There are no deposits or bonds for this permit application.
Inspection | Outcome | Requested | Scheduled | Date Complete |
---|---|---|---|---|
Framing Inspection | Partial Pass | 10/19/2017 (10:00 - 12:00) | 10/19/2017 | 10/19/2017 |
Walls only. Need above ceiling inspection. | ||||
Corrections:
Miscellaneous/Other
Outstanding
10/19/2017
Wall framing - A. Angled wall needs support, as top of wall is not to ceiling grid track, and is unsupported. B. Need above ceiling inspection, by building inspector as all ceiling tiles are installed after electrical lighting. Need confirmation of plenum ceiling having no combustibles and 25/50 flamespread minimum for all above ceiling materials. C. Restroom unisex sink when installed must provide minimum of 60 inches from the North finished wall at toilet to the north edge of the new sink, per ADA (MN STATE ACCESSIBILITY CODE.)
D. Note-accessible receptionist desk required, see plan.
|
||||
Fire Inspection Final | Passed | 11/17/2017 (8:00 - 10:00) | 11/17/2017 | 11/17/2017 |
Building Final Inspection | Passed | 11/17/2017 (8:00 - 10:00) | 11/17/2017 | 11/17/2017 |
Corrections:
Miscellaneous/Other
Comment Only
11/17/2017
Final - approved with fire, electrical, and plumbing finals.
|