Summary

PRBD201805687
Building
Expired
MINNEAPOLIS ES HOTEL LLC
Alteration/Remodel
Residential, hotels
This project consists of the renovation of 310 guest rooms as well as the public corridors, railings, stairs and various support staff spaces, all comprised on floors two through ten. No exterior envelope or landscape work will be performed. Exit stairs will remain open during construction to facilitate egress. No construction will take place on the ground floor unless required for plumbing or electrical connections from above.
06/08/2018
12/12/2018
03/01/2020

Locations

Permits

Permit Number: PRBD201805687

Building
Expired
12/12/2018
03/01/2020

Deposits & Bonds

There are no deposits or bonds for this permit application.

Inspections

Inspection Outcome Requested Scheduled Date Complete
Progress Inspection Pending
Corrections:


Miscellaneous/Other
Outstanding
08/06/2019
Rooms 1013 , 913, 813, 713, 613,513, needs smoke seals at doors between units. Install and call for inspection

Framing Inspection Pending 6/11/2019 (2:30 - 3:30)
Corrections:


Miscellaneous/Other
Outstanding
06/10/2019
Fire collars needed at toilet piping through floor. Hilti firestop needed at the tub trap. Ceiling to remain open for firestop inspection. 8th floor chase wall has piping that was incorrectly firestopped, contractor to add an 16 gage plate to the underside to correct Firestops.

Building Final Inspection Partial Pass 2/5/2019 (8:00 - 10:00) 2/5/2019 (AM) 02/05/2019
2/1/19 inspections cancelled - plumbing parts grounded in Boston. Will cb to R/S. vcarlson 01/31/2019 2:25 PM
Corrections:


Miscellaneous/Other
Comment Only
02/05/2019
10th floor approved for guest occupancy pending the installation of the emergency signage at doors , and the entry hardware where missing. Units1004,1013, 1015,1016 &1031 to be inspected and approved for final.

Building Final Inspection Partial Pass 2/7/2019 (8:00 - 10:00) 2/7/2019 (AM) 02/07/2019
2nd floor single and double bed units. A. Accessible units are being worked on and not available to the public at this time. See corrections.
Corrections:


Miscellaneous/Other
Comment Only
02/07/2019
2nd floor - partial pass for remodel existing guest rooms. A. 2 bed units have 36 inch between the beds minimum distance. OK. B. Accessible rooms are closed from public due to remodeling. C. No emergency lighting on the existing exit signage through out the hotel ? D. Provide partial final electrical inspection and fire marshal inspection for 2nd floor standard rooms only, prior to occupying these rooms .

Fire Inspection Final Partial Pass 2/4/2019 (8:00 - 10:00) 2/4/2019 (AM) 02/07/2019
2/1/19 inspections cancelled - plumbing parts grounded in Boston. Will cb to R/S. vcarlson 01/31/2019 2:25 PM
Corrections:


Miscellaneous/Other
Comment Only
02/07/2019
10th floor ok to occupy pending COB Building Inspections.

Fire Inspection Final Partial Pass 2/7/2019 (8:00 - 10:00) 2/7/2019 (AM) 02/07/2019
Corrections:


Miscellaneous/Other
Comment Only
02/07/2019
Ok to occupy 2nd floor pending COB Building Inspection

Building Final Inspection Partial Pass 3/5/2019 (10:00 - 12:00) 3/5/2019 (AM) 03/05/2019
Corrections:


Miscellaneous/Other
Comment Only
03/05/2019
Rooms 915,916,913, 922,931,904 are still not ready for turnover. All remaining rooms on 9th floor are approved for turnover and public use pending fire marshal approval and contractor to go through the rooms with double queen beds and adjust the bed spacing for 36”... (headboards to be adjusted to a min. 33” to provide the proper bed spacing.) Exiting signage for the rooms are being installed as inspection is in progress, all signage to be in each room for turnover.

Fire Inspection Final Partial Pass 3/5/2019 (10:00 - 12:00) 3/5/2019 (AM) 03/05/2019
Corrections:


Miscellaneous/Other
Comment Only
03/05/2019
9th floor approved as noted on COB Building Inspection report.

Progress Inspection Partial Pass 3/6/2019 (8:00 - 10:00) 3/6/2019 (AM) 03/06/2019
Corrections:


Miscellaneous/Other
Comment Only
03/06/2019
Rooms 1004, 231, approved for guest use and turnover.

Miscellaneous/Other
Carried Forward
03/06/2019
Room 1031 needs smoke detector and painted sprinkler head to be replaced. Room 204 needs painted sprinkler head replaced. Call for reinspection of these rooms.

Progress Inspection Partial Pass 3/11/2019 (12:30 - 2:30) 3/11/2019 (PM) 03/11/2019
Corrections:


Miscellaneous/Other
Resolved
03/11/2019
Room 1031 needs smoke detector and painted sprinkler head to be replaced. Room 204 needs painted sprinkler head replaced. Call for reinspection of these rooms.

Miscellaneous/Other
Comment Only
03/11/2019
Rooms: 811, 2- smoke detectors needed . 823 needs smoke detector. 802 to have exit signage Rooms to be completed...804,831,822,& 813, 815 & 816, No use for public of these rooms. Other rooms on 8th floor are approved for turnover and public use.

Progress Inspection Partial Pass 3/28/2019 (10:00 - 12:00) 3/28/2019 (AM) 03/28/2019
Corrections:


Miscellaneous/Other
Comment Only
03/28/2019
Rooms 1016,922, 931... approved for turnover to hotel and public use.

Progress Inspection Partial Pass 4/3/2019 (10:00 - 12:00) 4/3/2019 (AM) 04/03/2019
Corrections:


Miscellaneous/Other
Comment Only
04/03/2019
All Rooms on 7th for approved for final and public use except rooms 715,713.

Progress Inspection Partial Pass 4/10/2019 (10:00 - 12:00) 4/10/2019 (AM) 04/10/2019
Corrections:


Miscellaneous/Other
Comment Only
04/10/2019
All rentable rooms on 6th floor except units #,s 615 & conference room 613 that are still under construction.

Progress Inspection Partial Pass 5/1/2019 (12:30 - 2:30) 5/1/2019 (PM) 05/01/2019
Corrections:


Miscellaneous/Other
Comment Only
05/01/2019
5th floor all rooms except accessible rooms 515&532 approved for public use and final. Pending contractor punch list.

Progress Inspection Partial Pass 5/8/2019 (8:00 - 10:00) 5/8/2019 (AM) 05/08/2019
Corrections:


Miscellaneous/Other
Comment Only
05/08/2019
4th floor all rooms except rooms with Accessibility #’s 413,414, 415,432...approved for public use and turnover pending completion of punch list to rooms.

Progress Inspection Partial Pass 5/10/2019 (2:30 - 3:30) 5/10/2019 (PM) 05/10/2019
Corrections:


Miscellaneous/Other
Comment Only
05/10/2019
Framing and firestops at each floor of elevator lobbies ... approved

Progress Inspection Failed 5/22/2019 (10:00 - 12:00) 5/22/2019 (AM) 05/22/2019
Cancelled inspection for today. jsmidt 05/22/2019 10:59 AM
Corrections:


Miscellaneous/Other
Comment Only
05/22/2019
Inspection canceled

Progress Inspection Partial Pass 5/23/2019 (10:00 - 12:00) 5/23/2019 (AM) 05/23/2019
Corrections:


Miscellaneous/Other
Comment Only
05/23/2019
3rd floor units except for the rooms being worked on for accessibility approved for turnover except room 322 that need smoke detectors. Temp signs for evacuation plans in place and will be replaced with new ones by end of this month. Approved for turnover pending items listed are completed, and all misc punch work completed.

Progress Inspection Failed 6/7/2019 (10:00 - 12:00) 6/7/2019 (AM) 06/07/2019
Corrections:


Miscellaneous/Other
Carried Forward
06/10/2019
Floors 6 through 10 of the accessibility units viewed... 1) all holes from any abandoned plumbing or electrical needs to be metal plated on the underside and filled with concrete from above. Or an approved firestop system must be attained from a firestop design company, (ie. Hilti or 3M). 2) Any and all piping going through floor and roof must be firestopped with firecaulking all around piping with a caulking depth of 3/4”. 3) tub traps to be installed and the opening must be firestopped through floor. The large Hole opening is to be filled with mineral wool full depth, and a 18 gage steel plate to be adhered / fastened to slab. Fire caulking to be done around pipe and around the edges of the adhered metal plate. This assembly was a Hilti assembly designed for tub trap openings. Call for reinspection

Framing Inspection Partial Pass 6/10/2019 (10:00 - 12:00) 6/10/2019 (AM) 06/10/2019
Corrections:


Miscellaneous/Other
Comment Only
06/10/2019
Floors 6-10 framing and firestops in walls approved. Ok to cover walls only.

Miscellaneous/Other
Carried Forward
06/10/2019
Fire collars needed at toilet piping through floor. Hilti firestop needed at the tub trap. Ceiling to remain open for firestop inspection. 8th floor chase wall has piping that was incorrectly firestopped, contractor to add an 16 gage plate to the underside to correct Firestops.

Progress Inspection Not Ready 6/11/2019 (PM) 06/11/2019
Corrections:


Miscellaneous/Other
Resolved
06/11/2019
Floors 6 through 10 of the accessibility units viewed... 1) all holes from any abandoned plumbing or electrical needs to be metal plated on the underside and filled with concrete from above. Or an approved firestop system must be attained from a firestop design company, (ie. Hilti or 3M). 2) Any and all piping going through floor and roof must be firestopped with firecaulking all around piping with a caulking depth of 3/4”. 3) tub traps to be installed and the opening must be firestopped through floor. The large Hole opening is to be filled with mineral wool full depth, and a 18 gage steel plate to be adhered / fastened to slab. Fire caulking to be done around pipe and around the edges of the adhered metal plate. This assembly was a Hilti assembly designed for tub trap openings. Call for reinspection

Miscellaneous/Other
Comment Only
06/11/2019
Contractor not ready for inspection. Went over fire collars and installed at the toilet with contractor. Also went over grab bar requirements for the bathtubs with the contractor. Reinspection is required.

Progress Inspection Partial Pass 6/12/2019 (10:00 - 12:00) 6/12/2019 (AM) 06/12/2019
Corrections:


Miscellaneous/Other
Comment Only
06/12/2019
Floors seven, eight, nine, and 10 of the accessible bathrooms are approved with framing and fire stops. OK to start covering completely walls and ceilings.

Progress Inspection Partial Pass 6/24/2019 (8:00 - 3:30) 6/24/2019 (PM) 06/24/2019
Corrections:


Miscellaneous/Other
Carried Forward
06/24/2019
Accessible bathrooms or the rooms on the third ,fourth and fifth floors approved to cover. Contractor to send pictures of the three holes in the floor of the third being sealed with Concrete and Fire caulking to be done at low-voltage wires coming through concrete wall.

Progress Inspection Partial Pass 7/2/2019 (2:30 - 3:30) 7/2/2019 (PM) 07/02/2019
Corrections:


Miscellaneous/Other
Resolved
07/02/2019
Accessible bathrooms or the rooms on the third ,fourth and fifth floors approved to cover. Contractor to send pictures of the three holes in the floor of the third being sealed with Concrete and Fire caulking to be done at low-voltage wires coming through concrete wall.

Miscellaneous/Other
Comment Only
07/02/2019
Viewed the firestops in the accessible bathroom unit in room 215, All firestops approved and completed except for the shower. Shower firestop to be inspected. Rooms 532,432,332. Firestops and framing approved. Sprinkler inspection needed prior to covering.

Progress Inspection Partial Pass 7/29/2019 (10:00 - 12:00) 7/29/2019 (AM) 07/29/2019
Corrections:


Miscellaneous/Other
Carried Forward
07/29/2019
Rooms for accessibility.... 1015,915,815,715,615.... grab bars in the bathtubs are not at at the required accessibility heights. The removable seats need to be installed. No renting of these units till inspection is finaled. Unit 222 has a sloped floor that inspection will look into as to whether we can allow this.

Miscellaneous/Other
Comment Only
07/29/2019
Units 332,432,532 ... are approved to meet the accessibility requirements under the code and pertaining to existing conditions of the existing building code , within this building. These units can be rented out for public use.

Progress Inspection Partial Pass 8/6/2019 (12:30 - 2:30) 8/6/2019 (PM) 08/06/2019
Corrections:


Miscellaneous/Other
Resolved
08/06/2019
Rooms for accessibility.... 1015,915,815,715,615.... grab bars in the bathtubs are not at at the required accessibility heights. The removable seats need to be installed. No renting of these units till inspection is finaled. Unit 222 has a sloped floor that inspection will look into as to whether we can allow this.

Miscellaneous/Other
Carried Forward
08/06/2019
Rooms 1013 , 913, 813, 713, 613,513, needs smoke seals at doors between units. Install and call for inspection

Miscellaneous/Other
Comment Only
08/06/2019
All the “15” stack units to each floor and unit 222, and the “ 32” stack units that are accessible... approved for public use.

Fire Inspection Final Passed 9/3/2019 (8:00 - 10:00) 9/3/2019 (AM) 09/03/2019
Building Final Inspection Passed 9/3/2019 (8:00 - 10:00) 9/3/2019 (AM) 09/03/2019
Corrections:


Miscellaneous/Other
Comment Only
09/03/2019
Smoke seals installed at the 13 stack units...Final for all work with this permit approved.