Permit Application Status

PRBD201903700


You will only be able to view fees or view conditions if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRBD201903700
Building
Expired
VORANDESOTO LLC
Alteration/Repair/Replace
Not Required
Remodeling façade of Southport Shopping Center
04/22/2019
06/06/2019
06/07/2020

Locations

Permits

Permit Number: PRBD201903700

Building
Expired
06/06/2019
06/07/2020

Deposits & Bonds

There are no deposits or bonds for this permit application.

Inspections

Inspection Outcome Requested Scheduled Date Complete
Fire Inspection Final Pending
Building Final Inspection Pending
Footing Inspection Pending
Framing Inspection Pending
Lath Inspection Pending
Progress Inspection Pending
Footing Inspection Partial Pass 7/11/2019 (12:30 - 2:30) 7/11/2019 (PM) 07/11/2019
Two pier footings, and two stoop footings. - location at MGM liquors west end.
Framing Inspection Partial Pass 7/11/2019 (12:30 - 2:30) 7/11/2019 (PM) 07/11/2019
Progress only. Not ready.
Progress Inspection Partial Pass 08/02/2019
Demolition of building store front, and installing structural piers, stoop foundations. A. Individual protection and definition of tenant space front entry doors during construction. B. At this time things appear clean, exterior signage for tenants, and temporary covered entrance for tenants.
Progress Inspection Partial Pass 08/29/2019
Progress Inspection Partial Pass 09/10/2019
Progress: front parapet walls by steel stud. A. Need to use manufactured 90 degree clip from steel vertical studs to structure.
Framing Inspection Partial Pass 9/25/2019 (12:30 - 2:30) 9/25/2019 (PM) 09/25/2019
Progress.
Framing Inspection Partial Pass 10/04/2019
Structural iron, steel stud framing attached to structural iron, fire treated plywood sheathing and fire treated 2x4 attached to steel stud framing, gypsum board covering fire treated plywood and fire treated 2x4. 2 coat stucco with finish coat to follow. A. Need engineer approval of welding, structural iron, and steel stud fastening.
Lath Inspection Failed 10/23/2019
1st inspection - Stucco lathe inspection with grade 75 paper. A. Need to remove corner aid on vertical surface meeting horizontal surface, and install back to back casing beams per ASTM C 926.(stucco specification standards. )
Lath Inspection Partial Pass 10/31/2019
Progress- ASTM 96.
Progress Inspection Partial Pass 12/10/2019
Progress, on stucco, metal, for new store front exterior entry facades, for multiple existing tenants.