Inspection | Outcome | Requested | Scheduled | Date Complete |
---|---|---|---|---|
Framing Inspection | Partial Pass | 9/17/2019 (2:30 - 3:30) | 9/17/2019 (PM) | 09/17/2019 |
Various areas on second floor suite 200 for cushman Wakefield tenant, per plan. | ||||
Corrections:
Miscellaneous/Other
Carried Forward
09/17/2019
Framing. Need plumbing permit and rough in, need mechanical permit for diffusers and other, need fire sprinkler and fire alarm permits (huddle room strobe), need electrical permit.
A. Need building inspector back for above ceiling and for fire caulking ANY/ALL/FLOOR PENETRATIONS for new plumbing/other.
|
||||
Building Final Inspection | Passed w/ Conditions | 11/19/2019 (8:00 - 10:00) | 11/19/2019 (AM) | 11/19/2019 |
Final approved, contingent upon adding exit signs by fire marshal, and fire alarm test, with EM lighting by ceiling lites or wall packs. Note- green exit signs used, have no 90 minute EM lighting capability. | ||||
Fire Inspection Final | Not Ready | 11/19/2019 (8:00 - 10:00) | 11/19/2019 (AM) | 11/20/2019 |
Fire Inspection Final | Passed | 12/18/2019 |