PRBD201906932
There are no deposits or bonds for this permit application.
| Inspection | Outcome | Requested | Scheduled | Date Complete |
|---|---|---|---|---|
| Framing Inspection | Partial Pass | 8/7/2019 (8:00 - 10:00) | 8/7/2019 (AM) | 08/07/2019 |
| See corrections. | ||||
|
Corrections:
Miscellaneous/Other
Carried Forward
08/07/2019
Framing - basic walls to existing ceiling tile grid.
Corrections - A. FIRE SPRINKLER PERMIT REQUIRED - 1. DROPPING EXISTING HALLWAY CEILING 1 FT. 2. NOTE- EXISTING SPRINKLER HEAD IN TOP TRACK OF 1 NEW FRAMED WALL, MUST BE ACCESSIBLE FOR FIRE SPRINKLER CONTRACTOR TO REMOVE. B. LEAD LINED WALLS - PER X RAY MACHINE SPECS. PER CONTRACTOR THIS WILL BE INSTALLED BY FRAMING CONTRACTOR. C. PROVIDE ACCESSIBLE TRANSACTION COUNTER SPACE IN RECEPTION AREA, DRAWING IS NOT TO CODE. MIN. 36 INCH WIDE, MAX HEIGHT ABOVE FLOOR 36 INCH. D. EXIT SIGNS WITH EM LITES MUST BE LOCATED NORTH AND SOUTH END OF DROPPED HALLWAY CEILING. E. Call for above ceiling inspection for electrical, low voltage electrical (plenum,) HVAC, fire sprinkler, and building, prior to installing ceiling tiles.
|
||||
| Building Final Inspection | Issue TCO | 10/9/2019 (10:00 - 12:00) | 10/9/2019 (AM) | 10/09/2019 |
| Final - A. BREAKROOM SINK COUNTERTOP MAX HEIGHT ABOVE FINISHED FLOOR TO COUNTERTOP = 36 INCHES. ADD PLUMBING TRAP WRAP. B. ALL OTHER APPROVED. | ||||
| Fire Inspection Final | Passed | 10/9/2019 (10:00 - 12:00) | 10/9/2019 (AM) | 10/09/2019 |
| Building Final Inspection | Not Ready | 10/17/2019 (10:00 - 12:00) | 10/17/2019 (AM) | 10/17/2019 |
| Space is closed today . | ||||
|
Corrections:
Miscellaneous/Other
Comment Only
10/17/2019
Business is closed today due to exterior construction.
|
||||
| Building Final Inspection | Passed | 10/23/2019 | ||