Permit Application Status

PRBD202103685


You will only be able to view fees or view conditions if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRBD202103685
Building
Expired
LYNDALE PLAZA LLC
Alteration/Repair/Replace
Not Required
Renovating existing space to become a tea shop.
04/05/2021
06/02/2021
01/23/2022

Locations

Permits

Permit Number: PRBD202103685

Building
Expired
06/02/2021
01/23/2022

Deposits & Bonds

There are no deposits or bonds for this permit application.

Inspections

Inspection Outcome Requested Scheduled Date Complete
Building Final Inspection Pending
Framing Inspection Partial Pass 6/14/2021 (8:00 - 10:00) 6/14/2021 (AM) 06/14/2021
Framing - passed. A. Need above ceiling corrections. 1.North tenant separation wall requires gypsum patching holes, fire caulk penetrations around pipes, etc. B. Stuff roof deck flutes with mineral wool insulation.
Corrections:


Miscellaneous/Other
Outstanding
06/14/2021
Framing - passed. A. Patch all gypsum holes at north tenant one Hr rated gypsum separation to other tenants. B. Stuff open roof deck flutes using mineral wool, not fiberglass insulation, and call for re inspection before installing ceiling tiles. C. Call for fire marshal rough in for sprinkler coverage rough in. Your fire marshal is Kris Kaiser.

Progress Inspection Passed w/ Conditions 6/25/2021 (2:30 - 3:30) 6/25/2021 (PM) 06/25/2021
Above ceiling - penetrations in neighboring tenant walls - passed. Note - call for above ceiling inspections for fire sprinkler. Note - call for required plumbing rough in’s and environmental health inspections. Note - existing HVAC SYSTEM. A. NEW LOCATIONS FOR DIFFUSERS, with NEW INSULATED FLEX DUCT - PASSED.
Corrections:


Miscellaneous/Other
Outstanding
06/25/2021
Call for above ceiling trade inspections for fire sprinkler, AND electrical. Above ceiling for HVAC DIFFUSERS - PASSED PER B.POST.

Fire Inspection Final Failed 7/13/2021 (8:00 - 10:00) 7/13/2021 (AM) 07/13/2021
Corrections:


Miscellaneous/Other
Outstanding
07/13/2021
Remove plastic plant/foliage covering wall in the seating area or provide the information on the products flame spread and smoke index rating for further review.

Building Final Inspection Not Ready 7/13/2021 (8:00 - 10:00) 7/13/2021 (AM) 07/13/2021
Need environmental health final, need fire marshal final to remove artificial grass due to flame spread rating.
Fire Inspection Final Passed 7/15/2021 (2:30 - 3:30) 7/15/2021 (PM) 07/15/2021
Corrections:


Miscellaneous/Other
Resolved
07/15/2021
Remove plastic plant/foliage covering wall in the seating area or provide the information on the products flame spread and smoke index rating for further review.

Building Final Inspection Issue TCO 7/15/2021 (2:30 - 3:30) 7/15/2021 (PM) 07/15/2021
Existing restroom. A. New mirror installed. Bottom edge of mirror must be 40 inches off the finished floor. B. Move new paper towel dispenser installed to other side of wall and a max height above floor to bottom of dispenser to be 40 inches. C.TEMP OCCUPANCY PER ENVIRONMENTAL HEALTH FOR CORRECTIONS PER JESSICA JUTZ, JULY 22, 2021.
Framing Inspection Passed 07/27/2021
Corrections:


Miscellaneous/Other
Outstanding
06/14/2021
Framing - passed. A. Patch all gypsum holes at north tenant one Hr rated gypsum separation to other tenants. B. Stuff open roof deck flutes using mineral wool, not fiberglass insulation, and call for re inspection before installing ceiling tiles. C. Call for fire marshal rough in for sprinkler coverage rough in. Your fire marshal is Kris Kaiser.

Insulation Inspection Passed 07/27/2021
Not required.
Building Final Inspection Passed w/ Conditions 7/27/2021 (12:30 - 2:30) 7/27/2021 (PM) 07/27/2021
See corrections for environmental health. Building final inspection passed.
Corrections:


Miscellaneous/Other
Outstanding
07/27/2021
Complete environmental health final punch list. Final Building inspection - passed.