Permit Application Status

PRBD202111563


You will only be able to view fees or view conditions if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRBD202111563
Building
Finaled
SCA VENTURE LLC
Alteration/Repair/Replace
Not Required
Interior remodeling includes framing and carpentry
08/31/2021
09/23/2021
06/18/2022
12/20/2021

Locations

Permits

Permit Number: PRBD202111563

Building
Finaled
09/23/2021
06/18/2022

Deposits & Bonds

There are no deposits or bonds for this permit application.

Inspections

Inspection Outcome Requested Scheduled Date Complete
Framing Inspection Passed w/ Conditions 11/5/2021 (10:00 - 12:00) 11/5/2021 (AM) 11/05/2021
Corrections:


Miscellaneous/Other
Outstanding
11/05/2021
Wall framing - passed. A. Need fire sprinkler rough in when ready. B. Need to patch in drywall above electrical panel, above ceiling at tenant separation wall. C. Need above ceiling inspections prior to installing ceiling tiles for fire sprinkler, electrical, low voltage wiring, fire alarm wiring, prior to installing ceiling tile. D. Exit signage with Emergency lighting on the exit signs.

Progress Inspection Passed w/ Conditions 12/14/2021 (8:00 - 10:00) 12/14/2021 (AM) 12/14/2021
Need above ceiling inspection for fire sprinkler system with indoor vehicle parking. (Does this need Co2/No2 alarm. SEE MECHANICAL INSPECTOR.)
Fire Inspection Final Passed 12/17/2021 (10:00 - 12:00) 12/17/2021 (AM) 12/17/2021
Building Final Inspection Partial Pass 12/17/2021 (12:30 - 2:30) 12/17/2021 (PM) 12/17/2021
Corrections:


Miscellaneous/Other
Comment Only
12/17/2021
Above ceiling approved. See outstanding comments for correction. Approved for temp occupancy, call for final with the exit signs to be installed and viewed for final.

Miscellaneous/Other
Carried Forward
12/17/2021
Install exit sign at rear door to delineate rear exit, and lower front exit sign due to bulk head blocking view.

Building Final Inspection Passed 12/20/2021 (10:00 - 12:00) 12/20/2021 (AM) 12/20/2021
Corrections:


Miscellaneous/Other
Resolved
12/20/2021
Install exit sign at rear door to delineate rear exit, and lower front exit sign due to bulk head blocking view.

Miscellaneous/Other
Comment Only
12/20/2021
Corrections completed. Final for this scope of work and permit approved