Permit Application Status

PRBD202600373


You will only be able to view fees or view conditions if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRBD202600373
Building
Finaled
MOAC MALL HOLDINGS LLC
Alteration/Repair/Replace
Mercantile
Remodel of interior retail tenant space in a covered mall - Space #E264
01/14/2026
01/30/2026
09/07/2026
03/11/2026

Locations

Property
0102724310017

Address
60 EAST BROADWAY, BLOOMINGTON, MN 55425

264 East Broadway, Bloomington, MN 55425

Permits

Permit Number: PRBD202600373

Building
Finaled
01/30/2026
09/07/2026

Deposits & Bonds

There are no deposits or bonds for this permit application.

Inspections

Inspection Outcome Requested Scheduled Date Complete
Framing Inspection Passed w/ Conditions 2/18/2026 (2:30 - 3:30) 2/18/2026 (PM) 02/18/2026
Corrections:


Miscellaneous/Other
Comment Only
02/18/2026
Wall framing approved pending fire stop at through floor electrical in the wall. This can be viewed at the final inspection.

Progress Inspection Passed 02/18/2026
Corrections:


Miscellaneous/Other
Comment Only
02/18/2026
This progress inspection is for the approval to set up and stock this space. Sprinklers are active, exiting and accessibility are compliant. Approved for set up and stock only at this time. Call to set up final inspection prior to opening of space to public.

Building Final Inspection Not Ready 2/18/2026 (2:30 - 3:30) 2/18/2026 (PM) 02/18/2026
Corrections:


Miscellaneous/Other
Comment Only
02/18/2026
Not ready for final inspection at this time, see “progress inspection” dated 1/18/26 for stock and set up approval . Call for final inspection prior to opening this space to the public.

Fire Inspection Final Not Ready 2/18/2026 (2:30 - 3:30) 2/18/2026 (PM) 02/19/2026
Building Final Inspection Partial Pass 2/20/2026 (10:00 - 12:00) 2/20/2026 (AM) 02/20/2026
Corrections:


Miscellaneous/Other
Carried Forward
02/20/2026
Corrections… 1) install directional exit sign with arrow point to direction of exit by office, and turn exit and knock out arrow at office location to direct to exit behind office. 2) install cover plate to floor outlet in back storage of space. 3) at curtains, they need to have a minimum 36” opening at all times during business hours for full visibility and access to second exit. Reinspection of final needed , approved to occupy space at this time.

Fire Inspection Final Passed w/ Conditions 2/20/2026 (10:00 - 12:00) 2/20/2026 (AM) 02/20/2026
Add and adjust exit signs per building inspector
Building Final Inspection Passed 3/11/2026 (10:00 - 12:00) 3/11/2026 (AM) 03/11/2026
Corrections:


Miscellaneous/Other
Resolved
03/11/2026
Corrections… 1) install directional exit sign with arrow point to direction of exit by office, and turn exit and knock out arrow at office location to direct to exit behind office. 2) install cover plate to floor outlet in back storage of space. 3) at curtains, they need to have a minimum 36” opening at all times during business hours for full visibility and access to second exit. Reinspection of final needed , approved to occupy space at this time.

Miscellaneous/Other
Comment Only
03/11/2026
Corrections completed, final for this permit approved