PRDK202105015
There are no deposits or bonds for this permit application.
| Inspection | Outcome | Requested | Scheduled | Date Complete |
|---|---|---|---|---|
| Framing Inspection | Passed | 6/16/2021 (12:30 - 2:30) | 6/16/2021 (PM) | 06/16/2021 |
|
Corrections:
Miscellaneous/Other
Comment Only
06/16/2021
Beam and post replacement approved. Note, guard rail is existing to remain.
|
||||
| Building Final Inspection | Passed | 5/19/2021 (10:00 - 12:00) | 5/19/2021 (AM) | 06/16/2021 |
|
Corrections:
Miscellaneous/Other
Resolved
06/16/2021
Submit amended plan to include replaced portion of ledger board, post and both new beams with attachment to post.
1) New ledger connection with weatherproof membrane, fasteners used/pattern and flashng.
2) Positive connection with mechanical fasters footing to post and post to complete beam
3) Remove/replace fasters not approved for use with treated wood.
|
||||