Permit Application Status

PREL201710855


You will only be able to view fees or view conditions if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PREL201710855
Electrical
Finaled
MOAC MALL HOLDINGS LLC
Alteration/Remodel
Buildout of Final Game at Escape Game.
11/13/2017
11/14/2017
09/22/2018
03/26/2018

Locations

Permits

Permit Number: PREL201710855

Electrical
Finaled
11/14/2017
09/22/2018

Deposits & Bonds

There are no deposits or bonds for this permit application.

Inspections

Inspection Outcome Requested Scheduled Date Complete
Electrical Rough-in Inspection Passed 11/15/2017 (12:30 - 2:30) 11/15/2017 11/15/2017
Electrical Final Inspection Failed 3/21/2018 (10:00 - 12:00) 3/21/2018 03/21/2018
Corrections:


Miscellaneous/Other
Carried Forward
03/21/2018
All cables in plenum ceiling require plenum rating. EM lighting to be energized with loss of power to game room lighting. 120v components of apparatus and associated controls to be installed in j-boxes. All wiring to be done by MN licensed personnel. Abandoned wiring above ceiling to be removed. All electrical cables, boxes, and equipment to be supported and/or secured. Leave accessible outlets, cabinets, and controls for inspection.

Electrical Final Inspection Passed 3/26/2018 (8:00 - 10:00) 3/26/2018 03/26/2018
Corrections:


Miscellaneous/Other
Outstanding
03/21/2018
All cables in plenum ceiling require plenum rating. EM lighting to be energized with loss of power to game room lighting. 120v components of apparatus and associated controls to be installed in j-boxes. All wiring to be done by MN licensed personnel. Abandoned wiring above ceiling to be removed. All electrical cables, boxes, and equipment to be supported and/or secured. Leave accessible outlets, cabinets, and controls for inspection.