Permit Application Status

PREL201806143


You will only be able to view fees or view conditions if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PREL201806143
Electrical
Finaled
MSP BLOOMINGTON LLC
Other
Wire new hotel.
06/18/2018
09/19/2018
06/20/2020
12/23/2019

Locations

Permits

Permit Number: PREL201806143

Electrical
Finaled
09/19/2018
06/20/2020

Deposits & Bonds

There are no deposits or bonds for this permit application.

Inspections

Inspection Outcome Requested Scheduled Date Complete
Electrical Rough-in Inspection Partial Pass 9/26/2018 (8:00 - 10:00) 9/26/2018 09/26/2018
Corrections:


Miscellaneous/Other
Comment Only
09/26/2018
Site visit- city reviewed plan not on site. Visual ok at slab work.

Electrical Rough-in Inspection Partial Pass 10/26/2018 (8:00 - 10:00) 10/26/2018 (AM) 10/26/2018
Corrections:


Miscellaneous/Other
Comment Only
10/26/2018
Relocation of temp service. OK

Electrical Rough-in Inspection Partial Pass 1/7/2019 (8:00 - 10:00) 1/7/2019 (AM) 01/07/2019
Corrections:


Miscellaneous/Other
Comment Only
01/07/2019
Site visit only

Electrical Rough-in Inspection Partial Pass 1/15/2019 (8:00 - 10:00) 1/15/2019 (AM) 01/15/2019
Corrections:


Miscellaneous/Other
Comment Only
01/15/2019
Bonding OK at two wet niche fixtures. Call for all bonding inspections.

Electrical Rough-in Inspection Partial Pass 3/19/2019 (8:00 - 10:00) 3/19/2019 (AM) 03/19/2019
Corrections:


Miscellaneous/Other
Comment Only
03/19/2019
Questions at site. Exterior walls at first level RI OK. Exterior walls at 2nd and 3rd floors - limited view and access as insulation had been installed prior to inspection. Partial RI on units at 2nd floor.

Electrical Rough-in Inspection Partial Pass 3/20/2019 (10:00 - 12:00) 3/20/2019 (AM) 03/20/2019
Corrections:


Miscellaneous/Other
Comment Only
03/20/2019
Progress inspection at 2nd floor units. Inspector note there will be multiple RI inspection at units. 2nd floor guest suites RI OK. 2nd floor guest rooms partial, OK.

Electrical Rough-in Inspection Partial Pass 3/22/2019 (8:00 - 10:00) 3/22/2019 (AM) 03/22/2019
Corrections:


Miscellaneous/Other
Comment Only
03/22/2019
Units at 2nd floor RI OK

Miscellaneous/Other
Comment Only
03/22/2019
3rd floor guest rooms and 1/2 of the floor of the suites RI OK

Electrical Rough-in Inspection Partial Pass 3/25/2019 (10:00 - 12:00) 3/25/2019 (AM) 03/25/2019
Corrections:


Miscellaneous/Other
Comment Only
03/25/2019
RI OK at 3rd floor units. RI OK at 8 of 14 1st floor units.

Electrical Rough-in Inspection Partial Pass 3/29/2019 (10:00 - 12:00) 3/29/2019 (AM) 03/29/2019
Corrections:


Miscellaneous/Other
Comment Only
03/29/2019
RI OK @ 1st floor suites. 14 total.

Electrical Rough-in Inspection Partial Pass 4/8/2019 (8:00 - 10:00) 4/8/2019 (AM) 04/08/2019
Corrections:


Miscellaneous/Other
Comment Only
04/08/2019
RI OK For 4th floor guest rooms

Electrical Rough-in Inspection Partial Pass 4/9/2019 (12:30 - 2:30) 4/9/2019 (PM) 04/09/2019
Corrections:


Miscellaneous/Other
Comment Only
04/09/2019
RI OK For 4th floor units. RI OK for 1st floor units.

Electrical Rough-in Inspection Partial Pass 4/10/2019 (12:30 - 2:30) 4/10/2019 (PM) 04/10/2019
Corrections:


Miscellaneous/Other
Comment Only
04/10/2019
4th floor and 3rd floor corridor RI OK. Unit equipment to be on the same branch circuit as normal lighting in the area

Electrical Rough-in Inspection Partial Pass 4/18/2019 (12:30 - 2:30) 4/18/2019 (PM) 04/18/2019
Corrections:


Miscellaneous/Other
Comment Only
04/18/2019
2nd floor corridor OK

Electrical Rough-in Inspection Partial Pass 5/1/2019 (8:00 - 3:30) 5/1/2019 (AM) 05/01/2019
Corrections:


Miscellaneous/Other
Carried Forward
05/01/2019
Site visit and walk through with contractor. Verify available fault current at exterior lighting contractor.

Miscellaneous/Other
Carried Forward
05/01/2019
Site visit and walk through with contractor. Verify available fault current at exterior lighting contractor.

Electrical Rough-in Inspection Partial Pass 5/22/2019 (8:00 - 10:00) 5/22/2019 (AM) 05/22/2019
Corrections:


Miscellaneous/Other
Carried Forward
05/22/2019
Site visit and walk through with contractor. Verify available fault current at exterior lighting contractor.

Miscellaneous/Other
Comment Only
05/22/2019
Site visit and walk through with contractor. Verify available fault current at exterior lighting contractor.

Miscellaneous/Other
Comment Only
05/22/2019
Bonding at pool - 4 corners to pool shell, wet niche lights, cups for hand rails and ladders.

Miscellaneous/Other
Carried Forward
05/22/2019
Verify mount for handicapped pool access equipment and bond to any re-bar at perimeter. Call for additional bonding inspections as needed.

Miscellaneous/Other
Comment Only
05/22/2019
Walk through at first floor corridor OK.

Electrical Rough-in Inspection Partial Pass 5/30/2019 (12:30 - 2:30) 5/30/2019 (PM) 05/30/2019
Corrections:


Miscellaneous/Other
Carried Forward
05/30/2019
Site visit and walk through with contractor. Verify available fault current at exterior lighting contractor.

Miscellaneous/Other
Comment Only
05/30/2019
Verify mount for handicapped pool access equipment and bond to any re-bar at perimeter. Call for additional bonding inspections as needed.

Miscellaneous/Other
Comment Only
05/30/2019
1st floor ceilings and common areas- RI OK

Electrical Rough-in Inspection Partial Pass 6/6/2019 (Morning) 6/6/2019 (AM) 06/06/2019
Corrections:


Miscellaneous/Other
Resolved
06/06/2019
Site visit and walk through with contractor. Verify available fault current at exterior lighting contractor.

Miscellaneous/Other
Comment Only
06/06/2019
4th floor units hard lid ceilings OK

Electrical Rough-in Inspection Partial Pass 6/13/2019 (12:30 - 2:30) 6/13/2019 (PM) 06/14/2019
Corrections:


Miscellaneous/Other
Comment Only
06/14/2019
4th floor corridor above ceiling OK

Electrical Rough-in Inspection Partial Pass 7/1/2019 (12:30 - 2:30) 7/1/2019 (PM) 07/01/2019
Corrections:


Miscellaneous/Other
Comment Only
07/01/2019
3 floor units- hard lid above ceiling RI OK 1/2 3rd floor corridor above hard lid ceilings RI OK.

Electrical Rough-in Inspection Partial Pass 7/3/2019 (12:30 - 2:30) 7/3/2019 (PM) 07/03/2019
Corrections:


Miscellaneous/Other
Comment Only
07/03/2019
3 floor corridor hard lid RI OK

Electrical Rough-in Inspection Partial Pass 7/11/2019 (8:00 - 10:00) 7/11/2019 (AM) 07/11/2019
Corrections:


Miscellaneous/Other
Outstanding
07/11/2019
Bond at CT cabinet.

Miscellaneous/Other
Comment Only
07/11/2019
Service pass for release to Xcel.

Miscellaneous/Other
Outstanding
07/11/2019
Verify series ratings at all panelboards. Provide documentation.

Electrical Rough-in Inspection Partial Pass 7/12/2019 (10:00 - 12:00) 7/12/2019 (AM) 07/12/2019
release service to Xcel 4000 AMP 120/208 Volt tmiller 07/15/2019 3:48 PM
Corrections:


Miscellaneous/Other
Comment Only
07/12/2019
2nd floor unit hard lid ceilings RI - OK

Miscellaneous/Other
Comment Only
07/12/2019
4000 AMP 3 phase 120/208 volt service OK to release to Xcel. Correction OK at CT cabinet. Verify series ratings at panel boards.

Electrical Rough-in Inspection Partial Pass 7/18/2019 (12:30 - 2:30) 7/18/2019 (PM) 07/18/2019
Corrections:


Miscellaneous/Other
Comment Only
07/18/2019
2nd floor main corridor above ceiling RI OK

Electrical Rough-in Inspection Partial Pass 7/29/2019 (10:00 - 12:00) 7/29/2019 (AM) 07/29/2019
Corrections:


Miscellaneous/Other
Carried Forward
07/29/2019
Front canopy lighting RI

Electrical Rough-in Inspection Partial Pass 8/9/2019 (12:30 - 2:30) 8/9/2019 (PM) 08/09/2019
Corrections:


Miscellaneous/Other
Comment Only
08/09/2019
Front canopy lighting RI

Miscellaneous/Other
Comment Only
08/09/2019
Canopy ok to cover- RI OK

Electrical Rough-in Inspection Partial Pass 9/5/2019 (10:00 - 12:00) 9/5/2019 (AM) 09/05/2019
Corrections:


Miscellaneous/Other
Comment Only
09/05/2019
1st floor corridor and units - hard lid ceilings RI-OK

Miscellaneous/Other
Carried Forward
09/05/2019
Verify gen-set listings.

Electrical Rough-in Inspection Partial Pass 9/12/2019 (12:30 - 2:30) 9/12/2019 (PM) 09/12/2019
Corrections:


Miscellaneous/Other
Carried Forward
09/12/2019
Verify gen-set listings.

Miscellaneous/Other
Comment Only
09/12/2019
Above ceiling at pool deck area. call for re-inspection for bonding of all fixed metal parts. Luminaires will require GFCI protection. Verify "lens" type- totally enclosed required where located less than 5 foot horizontal from inside wall of pool.

Electrical Rough-in Inspection Partial Pass 9/16/2019 (12:30 - 2:30) 9/16/2019 (PM) 09/16/2019
Corrections:


Miscellaneous/Other
Carried Forward
09/16/2019
Verify gen-set listings.

Miscellaneous/Other
Comment Only
09/16/2019
Bonding OK at above pool and pool deck.

Electrical Rough-in Inspection Partial Pass 9/26/2019 (8:00 - 10:00) 9/26/2019 (AM) 09/26/2019
Corrections:


Miscellaneous/Other
Resolved
09/26/2019
Verify gen-set listings.

Miscellaneous/Other
Comment Only
09/26/2019
Above ceiling at main floor lobby and common areas RI- OK.

Electrical Rough-in Inspection Partial Pass 9/27/2019 (12:30 - 2:30) 9/27/2019 (PM) 09/27/2019
Corrections:


Miscellaneous/Other
Comment Only
09/27/2019
Ceiling RI OK at main level- gym area

Electrical Rough-in Inspection Partial Pass 10/22/2019 (10:00 - 12:00) 10/22/2019 (AM) 10/22/2019
Corrections:


Miscellaneous/Other
Comment Only
10/22/2019
4th floor corridor- ceilings OK

Electrical Final Inspection Partial Pass 10/30/2019 (10:00 - 12:00) 10/30/2019 (AM) 10/30/2019
Corrections:


Miscellaneous/Other
Comment Only
10/30/2019
Plug checks and walk through Units- # 401 through #432. Verbal- provide GFCI protection for receptacle wall outlet within six foot of sink. Install box extension at bathroom wall openings.

Electrical Final Inspection Partial Pass 11/1/2019 (10:00 - 12:00) 11/1/2019 (AM) 11/01/2019
Corrections:


Miscellaneous/Other
Comment Only
11/01/2019
Partial final- 4th Floor units- Verify AFCI

Electrical Final Inspection Partial Pass 11/4/2019 (10:00 - 12:00) 11/4/2019 (AM) 11/04/2019
Corrections:


Miscellaneous/Other
Comment Only
11/04/2019
Unit walk through- final #301- #331 odd side OK

Electrical Final Inspection Not Ready 11/6/2019 (10:00 - 12:00) 11/6/2019 (AM) 11/06/2019
Corrections:


Miscellaneous/Other
Carried Forward
11/06/2019
AFCI protection must comply with NEC 210.12 (C)

Electrical Final Inspection Partial Pass 11/13/2019 (10:00 - 12:00) 11/13/2019 (AM) 11/13/2019
Corrections:


Miscellaneous/Other
Outstanding
11/06/2019
AFCI protection must comply with NEC 210.12 (C)

Miscellaneous/Other
Comment Only
11/13/2019
Final units - 302 - 332 even number rooms and 335-355 odd number rooms. OK

Electrical Final Inspection Partial Pass 11/15/2019 (10:00 - 12:00) 11/15/2019 (AM) 11/15/2019
Corrections:


Miscellaneous/Other
Comment Only
11/15/2019
3rd floor units- plug check complete

Miscellaneous/Other
Comment Only
11/15/2019
Elevator equipment room OK

Miscellaneous/Other
Comment Only
11/15/2019
Listing and labeling of laundry room equipment OK

Electrical Final Inspection Partial Pass 11/19/2019 (10:00 - 12:00) 11/19/2019 (AM) 11/19/2019
Corrections:


Miscellaneous/Other
Comment Only
11/19/2019
Walkthrough of units # 201 through # 232 plug checks OK

Electrical Final Inspection Partial Pass 11/21/2019 (10:00 - 12:00) 11/21/2019 (AM) 11/21/2019
Corrections:


Miscellaneous/Other
Comment Only
11/21/2019
Plug checks OK at # 101 through # 114

Electrical Final Inspection Partial Pass 11/22/2019 (10:00 - 12:00) 11/22/2019 (AM) 11/22/2019
Corrections:


Miscellaneous/Other
Comment Only
11/22/2019
1st floor ceilings RI OK

Miscellaneous/Other
Outstanding
11/22/2019
Laundry chute control box is listed but does not bear Class 2 labels- treat as power circuit- must be performed by licensed electrical contractor

Miscellaneous/Other
Outstanding
11/22/2019
Verify SCCR ratings to OCP settings per nameplate at transfer switch

Electrical Final Inspection Partial Pass 11/25/2019 (10:00 - 12:00) 11/25/2019 (AM) 11/25/2019
Corrections:


Miscellaneous/Other
Comment Only
11/25/2019
Review/ inspection of HVAC equipment, Including roof top units- verbal for OCP sizing at mini split units.

Electrical Final Inspection Partial Pass 11/26/2019 (10:00 - 12:00) 11/26/2019 (AM) 11/26/2019
Corrections:


Miscellaneous/Other
Comment Only
11/26/2019
2nd Floor units- plug check OK- complete

Electrical Final Inspection Partial Pass 11/27/2019 (10:00 - 12:00) 11/27/2019 (AM) 11/27/2019
Corrections:


Miscellaneous/Other
Comment Only
11/27/2019
1st floor units - plug checks OK

Electrical Final Inspection Partial Pass 12/2/2019 (10:00 - 12:00) 12/2/2019 (AM) 12/02/2019
Corrections:


Miscellaneous/Other
Comment Only
12/02/2019
Power outage at inspection. Walk through with contractor for life safety lighting inspection- function OK

Electrical Final Inspection Passed 12/3/2019 (10:00 - 12:00) 12/3/2019 (AM) 12/03/2019
Corrections:


Miscellaneous/Other
Comment Only
12/03/2019
Testing of AFCI function for units without panelboard in unit- OK

Electrical Final Inspection Partial Pass 12/4/2019 (10:00 - 12:00) 12/4/2019 (AM) 12/04/2019
Corrections:


Miscellaneous/Other
Comment Only
12/04/2019
Routine walk through with foreman- laundry whips OK Exterior lighting requires readily accessible GFCI protection.

Miscellaneous/Other
Comment Only
12/04/2019
Replacement of non- TR modular receptacles at headboards- spot checks for replacement OK

Electrical Final Inspection Partial Pass 12/5/2019 (10:00 - 12:00) 12/5/2019 (AM) 12/05/2019
Corrections:


Miscellaneous/Other
Comment Only
12/05/2019
Progress inspection OK- signed permit card for partial final

Electrical Final Inspection Partial Pass 12/6/2019 (10:00 - 12:00) 12/6/2019 (AM) 12/06/2019
Corrections:


Miscellaneous/Other
Comment Only
12/06/2019
Progress inspection at pool equipment room

Electrical Final Inspection Partial Pass 12/12/2019 (10:00 - 12:00) 12/12/2019 (AM) 12/12/2019
Corrections:


Miscellaneous/Other
Comment Only
12/12/2019
Routine progress inspection

Electrical Final Inspection Partial Pass 12/13/2019 (10:00 - 12:00) 12/13/2019 (AM) 12/13/2019
Corrections:


Miscellaneous/Other
Comment Only
12/13/2019
Review of modifications at elevator equipment room.

Electrical Final Inspection Partial Pass 12/20/2019 (10:00 - 12:00) 12/20/2019 (AM) 12/20/2019
Corrections:


Miscellaneous/Other
Comment Only
12/20/2019
Pool and pool equipment room final OK

Electrical Final Inspection Passed 12/23/2019 (10:00 - 12:00) 12/23/2019 (AM) 12/23/2019
Corrections:


Miscellaneous/Other
Comment Only
12/23/2019
Final electrical inspection approved.