PREL202013558
There are no deposits or bonds for this permit application.
Inspection | Outcome | Requested | Scheduled | Date Complete |
---|---|---|---|---|
Electrical Final Inspection | Failed | 3/26/2021 (12:30 - 2:30) | 3/26/2021 (PM) | 03/26/2021 |
I called back to schedule electrical after rescheduling Hazard inspection(1/26/2021). And person plans to call back to schedule electrical. jms 1/22/2021 | ||||
Corrections:
Miscellaneous/Other
Carried Forward
03/26/2021
Branch circuit extension of existing laundry circuit-
Strap NM cable to code from existing ceiling J-box to wiremold sleeve.
Provide AFCI/GFCI Type TR receptacle outlet or provide AFCI protection at panelboard.
Call for re-inspection.
|
||||
Electrical Final Inspection | Passed | 10/15/2021 (12:30 - 2:30) | 10/15/2021 (PM) | 10/15/2021 |
Corrections:
Miscellaneous/Other
Comment Only
10/15/2021
Branch circuit extension of existing laundry circuit-
Strap NM cable to code from existing ceiling J-box to wiremold sleeve.
Provide AFCI/GFCI Type TR receptacle outlet or provide AFCI protection at panelboard.
Call for re-inspection.
|
||||
Miscellaneous/Other
Comment Only
10/15/2021
Contractor never came back for correction.
New homeowner hired electrical contractor to change out.
Visual OK.
|