Permit Application Status

PRFD202203861


You will only be able to view fees or view conditions if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRFD202203861
Foundation
Finaled
WALSER REAL ESTATE LLC
Other
Business
Storage, moderate hazard
Piling and foundation for Walser Toyota new dealership and corporate office building
04/13/2022
06/22/2022
05/16/2023
11/17/2022

Locations

Permits

Permit Number: PRFD202203861

Foundation
Finaled

Deposits & Bonds

There are no deposits or bonds for this permit application.

Inspections

Inspection Outcome Requested Scheduled Date Complete
Footing Inspection Pending
Footing Inspection Partial Pass 7/25/2022 (12:30 - 2:30) 7/25/2022 (PM) 07/25/2022
Miscellaneous/Other
Comment Only
07/25/2022
Progress - 9 - pile cap footings - A. #8 rebars, per plan, poured on new piled good footings. Location southwest corner area. B. Subject to special inspections approval.

Footing Inspection Passed 7/27/2022 (12:30 - 2:30) 7/27/2022 (PM) 07/27/2022
Footing Inspection Passed 8/1/2022 (8:00 - 10:00) 8/1/2022 (AM) 08/01/2022
Miscellaneous/Other
Comment Only
08/01/2022
Multiple pile cap footings as per plan marked in field approved.

Footing Inspection Passed 8/3/2022 (10:00 - 12:00) 8/3/2022 (AM) 08/03/2022
Miscellaneous/Other
Comment Only
08/03/2022
Ten pile caps as per plan marked in field approved.

Footing Inspection Passed 8/5/2022 (10:00 - 12:00) 8/5/2022 (AM) 08/05/2022
Miscellaneous/Other
Comment Only
08/05/2022
13 pile caps as per drawings marked in field approved.

Footing Inspection Not Ready 8/8/2022 (12:30 - 2:30) 8/8/2022 (PM) 08/08/2022
Footing Inspection Passed 8/9/2022 (12:30 - 2:30) 8/9/2022 (PM) 08/09/2022
Miscellaneous/Other
Comment Only
08/09/2022
For pile caps as per marked drawings approved.

Footing Inspection Passed 8/11/2022 (2:30 - 3:30) 8/11/2022 (PM) 08/11/2022
Miscellaneous/Other
Comment Only
08/11/2022
Nine pile caps as per plan marked in Field approved.

Footing Inspection Passed 8/15/2022 (10:00 - 12:00) 8/15/2022 (AM) 08/15/2022
Miscellaneous/Other
Comment Only
08/15/2022
Eight pile caps as per plan approved.

Footing Inspection Passed 8/16/2022 (10:00 - 12:00) 8/16/2022 (AM) 08/16/2022
Miscellaneous/Other
Comment Only
08/16/2022
Four pads on column line J and one pad on column H7 as per marked plans approved.

Footing Inspection Passed 8/18/2022 (10:00 - 12:00) 8/18/2022 (AM) 08/18/2022
Miscellaneous/Other
Comment Only
08/18/2022
Eight pile caps as per plan marked in field approved.

Footing Inspection Passed 8/24/2022 (12:30 - 2:30) 8/24/2022 (PM) 08/24/2022
Miscellaneous/Other
Comment Only
08/24/2022
Seven Pile caps total on column line G approved. Note adjust as required to maintain 3 inches clearance.

Footing Inspection Passed 8/31/2022 (10:00 - 12:00) 8/31/2022 (AM) 08/31/2022
Miscellaneous/Other
Comment Only
08/31/2022
One pile cap and partial grade beam on south and east walls as per drawing marked in field approved.

Footing Inspection Passed 9/1/2022 (10:00 - 12:00) 9/1/2022 (AM) 09/01/2022
Miscellaneous/Other
Comment Only
09/01/2022
Three pile caps as per marked drawings approved.

Footing Inspection Passed 9/2/2022 (8:00 - 10:00) 9/2/2022 (AM) 09/02/2022
Miscellaneous/Other
Comment Only
09/02/2022
To pile caps per drawings approved.

Footing Inspection Passed 9/6/2022 (8:00 - 10:00) 9/6/2022 (AM) 09/06/2022
Miscellaneous/Other
Comment Only
09/06/2022
Rebar for car wash pad: #6 bar @ 12” o.c., E.W., top and bottom, approved.

Footing Inspection Passed 9/7/2022 (10:00 - 12:00) 9/7/2022 (AM) 09/07/2022
Miscellaneous/Other
Comment Only
09/07/2022
To pile caps per drawings approved.

Footing Inspection Passed 9/8/2022 (12:30 - 2:30) 9/8/2022 (PM) 09/08/2022
Miscellaneous/Other
Comment Only
09/08/2022
Eight pile caps as per marked plan approved.

Footing Inspection Passed 9/12/2022 (10:00 - 12:00) 9/12/2022 (AM) 09/12/2022
Miscellaneous/Other
Comment Only
09/12/2022
Four grade beams as per plan marked in field approved.

Footing Inspection Passed 9/13/2022 (10:00 - 12:00) 9/13/2022 (AM) 09/13/2022
Miscellaneous/Other
Comment Only
09/13/2022
Six pile caps as per marked drawings approved.

Footing Inspection Passed 9/14/2022 (12:30 - 2:30) 9/14/2022 (PM) 09/14/2022
Miscellaneous/Other
Comment Only
09/14/2022
Five pile caps approved.

Footing Inspection Passed 9/15/2022 (12:30 - 2:30) 9/15/2022 (PM) 09/15/2022
Miscellaneous/Other
Comment Only
09/15/2022
Grade beams and pile caps as per drawing approved.

Footing Inspection Passed 9/19/2022 (10:00 - 12:00) 9/19/2022 (AM) 09/19/2022
Miscellaneous/Other
Comment Only
09/19/2022
Three pile caps as per drawings marked infield approved.

Footing Inspection Passed 9/20/2022 (10:00 - 12:00) 9/20/2022 (AM) 09/20/2022
Miscellaneous/Other
Comment Only
09/20/2022
Four pile caps per marked drawings approved.

Footing Inspection Passed 9/21/2022 (10:00 - 12:00) 9/21/2022 (AM) 09/21/2022
Miscellaneous/Other
Comment Only
09/21/2022
Five pile caps as per field marked drawings approved.

Footing Inspection Passed 9/22/2022 (10:00 - 12:00) 9/22/2022 (AM) 09/22/2022
Miscellaneous/Other
Comment Only
09/22/2022
Three pile caps as per drawings approved.

Footing Inspection Passed 9/23/2022 (10:00 - 12:00) 9/23/2022 (AM) 09/23/2022
Miscellaneous/Other
Comment Only
09/23/2022
Multiple grade beams in South West corner as per drawings marked in field approved.

Footing Inspection Passed 9/30/2022 (10:00 - 12:00) 9/30/2022 (AM) 10/02/2022
Miscellaneous/Other
Comment Only
10/02/2022
Multiple pile cabs and grade beams inspected on Saturday, October 1 as per plans marked in field approved.

Footing Inspection Passed 10/7/2022 (12:30 - 2:30) 10/7/2022 (PM) 10/07/2022
Miscellaneous/Other
Comment Only
10/07/2022
Partial grade beam along west wall approved.

Footing Inspection Passed 10/11/2022 (10:00 - 12:00) 10/11/2022 (AM) 10/12/2022
Miscellaneous/Other
Comment Only
10/12/2022
Pile caps and grade beams as per plan marked in field approved.

Footing Inspection Passed 10/17/2022 (12:30 - 2:30) 10/17/2022 (PM) 10/17/2022
Miscellaneous/Other
Comment Only
10/17/2022
Multiple pile camps and short columns as per plan marked in field approved.

Footing Inspection Passed 10/19/2022 (10:00 - 12:00) 10/19/2022 (AM) 10/19/2022
Miscellaneous/Other
Comment Only
10/19/2022
Pile caps and grade beams as per marked drawings approved.

Footing Inspection Passed 10/21/2022 (10:00 - 12:00) 10/21/2022 (AM) 10/21/2022
Miscellaneous/Other
Comment Only
10/21/2022
Multiple pile caps as per plan marked in field approved.

Footing Inspection Passed 10/25/2022 (10:00 - 12:00) 10/25/2022 (AM) 10/25/2022
Miscellaneous/Other
Comment Only
10/25/2022
11 pile camp footings as per marked drawings approved.

Footing Inspection Passed 10/27/2022 (10:00 - 12:00) 10/27/2022 (AM) 10/27/2022
Miscellaneous/Other
Comment Only
10/27/2022
Five pile caps as per drawings marked in field approved.

Footing Inspection Passed 10/31/2022 (10:00 - 12:00) 10/31/2022 (AM) 10/31/2022
Miscellaneous/Other
Comment Only
10/31/2022
Five pile caps as per approved drawings

Footing Inspection Passed 11/2/2022 (8:00 - 10:00) 11/2/2022 (AM) 11/02/2022
Miscellaneous/Other
Comment Only
11/02/2022
Remaining grade beam along east wall approved.

Footing Inspection Passed 11/4/2022 (10:00 - 12:00) 11/4/2022 (AM) 11/04/2022
Miscellaneous/Other
Comment Only
11/04/2022
Portion of poured wall at west wall approved.

Footing Inspection Passed 11/9/2022 (8:00 - 10:00) 11/9/2022 (AM) 11/09/2022
Miscellaneous/Other
Comment Only
11/09/2022
Remaining north foundation wall approved.

Footing Inspection Passed 11/10/2022 (2:30 - 3:30) 11/10/2022 (PM) 11/10/2022
Miscellaneous/Other
Comment Only
11/10/2022
Progress inspection of grade beams in precast area approved. Call for inspection when forms are in place.

Building Final Inspection Passed 11/17/2022
Footing Inspection Passed 11/17/2022 (8:00 - 10:00) 11/17/2022 (AM) 11/17/2022