PRFD202502320
There are no deposits or bonds for this permit application.
| Inspection | Outcome | Requested | Scheduled | Date Complete |
|---|---|---|---|---|
| Building Final Inspection | Pending | |||
| Footing Inspection | Passed | 3/25/2025 (10:00 - 12:00) | 3/25/2025 (AM) | 03/25/2025 |
|
Corrections:
Miscellaneous/Other
Comment Only
03/25/2025
Expanded footing improvements along north wall approved.
|
||||
| Footing Inspection | Passed | 4/1/2025 (8:00 - 10:00) | 4/1/2025 (AM) | 04/01/2025 |
|
Corrections:
Miscellaneous/Other
Comment Only
04/01/2025
Miscellaneous pad footings along east and west walls and pad footings along column line 3B approved.
|
||||
| Footing Inspection | Passed | 4/3/2025 (8:00 - 10:00) | 4/3/2025 (AM) | 04/03/2025 |
|
Corrections:
Miscellaneous/Other
Comment Only
04/03/2025
5 piers in area B... approved
|
||||
| Progress Inspection | Passed | 4/7/2025 (8:00 - 10:00) | 4/7/2025 (AM) | 04/07/2025 |
| Vapor Barrier test | ||||
|
Corrections:
Miscellaneous/Other
Comment Only
04/07/2025
Viewed various sections where rebar , underslab poly and thickened footing of slab infills throughout areas... approved to place concrete .
Veiwed the progress of the underpinning of double mat footing in the arena area where ramp will be located... progress of the infill is approved.
|
||||
| Progress Inspection | Passed | 4/9/2025 (10:00 - 12:00) | 4/9/2025 (AM) | 04/09/2025 |
|
Corrections:
Miscellaneous/Other
Comment Only
04/09/2025
First progress inspection of underpinning walls in rink number one approved.
|
||||
| Progress Inspection | Passed | 4/14/2025 (10:00 - 12:00) | 4/14/2025 (AM) | 04/14/2025 |
|
Corrections:
Miscellaneous/Other
Comment Only
04/14/2025
Reinforced slab inspection at West side, toilet rooms, trench in rink area number two between column lines C and D, south east toilet room at rink number two approved. Progress inspection of Reinforced structural walls in rink number one approved.
|
||||
| Progress Inspection | Passed | 4/23/2025 (8:00 - 10:00) | 4/23/2025 (AM) | 04/23/2025 |
| Reinforced slab in section a concession area and section a toilet room areas approved. Inspection of reinforced walls in number one approved. | ||||
|
Corrections:
Miscellaneous/Other
Comment Only
04/15/2025
Reinforced slab inspections for concessions and remaining toilet rooms approved. Progress inspection of reinforced walls in number one approved.
|
||||
|
Miscellaneous/Other
Comment Only
04/23/2025
Miscellaneous pads, trenches, and slab preparation for bleacher area in rink number three approved.
|
||||
| Progress Inspection | Passed | 5/28/2025 (8:00 - 10:00) | 5/28/2025 (AM) | 05/28/2025 |
|
Corrections:
Miscellaneous/Other
Comment Only
05/28/2025
Reinforced slab at North wall of arena number three approved. Stadia seating at south wall of arena number three approved. Rebar for rink slab in arena number one approved.
|
||||