Summary

PRPK201910523
Parking Lot
Finaled
LYNDALE PLAZA LLC
Other
Not Required
Overlay existing front lot. Patch rear alley.
09/09/2019
09/23/2019
05/17/2020
11/19/2019

Locations

Permits

Permit Number: PRPK201910523

Parking Lot
Finaled
09/23/2019
05/17/2020

Deposits & Bonds

There are no deposits or bonds for this permit application.

Inspections

Inspection Outcome Requested Scheduled Date Complete
Building Final Inspection Failed 9/25/2019 (12:30 - 2:30) 9/25/2019 (PM) 09/25/2019
A. Approx. 128 new parking spaces - requires 5 accessible parking spaces, or 5 required over 100 existing parking spaces. 4 accessible parking spaces only provided. B. All signage must be provided at the center front head of each accessible parking space, and at the center head of each unload space. C. 5 - Accessible parking space signage is required due to total count of parking lot spaces. D. Unload space signage must state (No Parking.) E. Accessible parking signage must be MN State approved, $200 fine. F. All signage must be installed permanently into the asphalt on a approved steel sign post, to a height from the parking lot surface of 5 ft to center of each sign. G. The 3 new parking spaces added to the north side of the building must be removed, as a min of 20 feet of clear drive lane surface for fire truck access around the building must be maintained.
Building Final Inspection Partial Pass 11/6/2019 (8:00 - 10:00) 11/6/2019 (AM) 11/06/2019
See corrections.
Corrections:


Miscellaneous/Other
Carried Forward
11/06/2019
Signage and 5 accessible stalls passed. A. **Need to remove at the north end of the building, the white stripe parking stalls, allowing for 20 feet of clearance width around the north end of the building for fire truck access. B. In addition, could also suggest placing a sign on the north side of building stating no parking fire lane. C. Call for final when ready.

Building Final Inspection Passed w/ Conditions 11/19/2019 (10:00 - 12:00) 11/19/2019 (AM) 11/19/2019
Need to keep fire truck drive lane on north end of building min 20 ft clear for fire truck access.
Corrections:


Miscellaneous/Other
Outstanding
11/06/2019
Signage and 5 accessible stalls passed. A. **Need to remove at the north end of the building, the white stripe parking stalls, allowing for 20 feet of clearance width around the north end of the building for fire truck access. B. In addition, could also suggest placing a sign on the north side of building stating no parking fire lane. C. Call for final when ready.