Summary

PRPL201703975
Plumbing
Finaled
PHD PROPERTIES LLC
New
Complete plumbing system in new 32 unit apartment building--see plans for details.
05/19/2017
07/06/2017
08/27/2018
02/28/2018

Locations

Permits

Permit Number: PRPL201703975

Plumbing
Finaled
07/06/2017
08/27/2018

Deposits & Bonds

There are no deposits or bonds for this permit application.

Inspections

Inspection Outcome Requested Scheduled Date Complete
Plumbing Rough-in Inspection Partial Pass 8/1/2017 (8:00 - 10:00) 8/1/2017 08/01/2017
Corrections:


Miscellaneous/Other
Comment Only
08/01/2017
5# on complete underground sanitary-ok to cover. Flam. waste also tested. Mechanical room underground tested. Greg to stub future 4" waste line in for new trash room on existing building.

Plumbing Rough-in Inspection Partial Pass 8/21/2017 (10:00 - 12:00) 8/21/2017 08/21/2017
Corrections:


Miscellaneous/Other
Comment Only
08/21/2017
5# on 4" pvc running from existing building to new building. Clean outs installed, foam covering pipe. Plumber to update drawings

Plumbing Rough-in Inspection Passed 9/13/2017 (12:30 - 2:30) 9/13/2017 09/13/2017
Corrections:


Miscellaneous/Other
Comment Only
09/13/2017
Visual inspection of 1st floor waste and vent. Visual inspection of units 4,6,7 on 2nd floor.

Plumbing Rough-in Inspection Passed 10/10/2017 (12:30 - 2:30) 10/10/2017 10/10/2017
Corrections:


Miscellaneous/Other
Comment Only
10/10/2017
All waste and vent airtested from roof to ceiling of garage. Ok to cover.

Plumbing Rough-in Inspection Not Ready 10/13/2017 (8:00 - 10:00) 10/13/2017 10/13/2017
Corrections:


Miscellaneous/Other
Carried Forward
10/13/2017
Inspection rescheduled for Monday. Not enough time scheduled.

Plumbing Rough-in Inspection Passed 10/16/2017 (2:30 - 3:30) 10/16/2017 10/17/2017
Corrections:


Miscellaneous/Other
Outstanding
10/13/2017
Inspection rescheduled for Monday. Not enough time scheduled.

Miscellaneous/Other
Comment Only
10/17/2017
Visual walk through. Nail plate, finish fire caulking, support stacks at each story, call for reinspection.

Plumbing Rough-in Inspection Passed 11/7/2017 (2:30 - 3:30) 11/7/2017 11/08/2017
Plumbing Rough-in Inspection Passed 12/4/2017 (2:30 - 3:30) 12/4/2017 12/04/2017
Corrections:


Miscellaneous/Other
Comment Only
12/04/2017
5# on all parking garage above ground piping. 5# on storm as well. Could not find blue sheets in job trailer to update, job sup. and plumbing foreman not aware of a book or any blue sheets.

Plumbing Final Inspection Partial Pass 1/30/2018 (12:30 - 2:30) 1/30/2018 01/30/2018
Corrections:


Miscellaneous/Other
Outstanding
01/30/2018
Dishwasher in 205 not set properly. Pop-up in 207. Manometer test approved. First and 2nd floor walk through completed. Replace Jym caps with blind plugs in the garage.

Plumbing Final Inspection Partial Pass 2/1/2018 (2:30 - 3:30) 2/1/2018 02/02/2018
Plumbing Final Inspection Passed 2/28/2018 02/28/2018
Corrections:


Comment Only
02/28/2018
Elevator pan drains have been inspected and meet the code and are approved.