Permit Application Status

PRPL201706344


You will only be able to view fees or view conditions if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRPL201706344
Plumbing
Finaled
MOAC MALL HOLDINGS LLC
Alteration/Remodel
New bakery buildout.
07/19/2017
07/20/2017
01/06/2020
09/20/2017

Locations

Permits

Permit Number: PRPL201706344

Plumbing
Finaled
07/20/2017
01/06/2020

Deposits & Bonds

There are no deposits or bonds for this permit application.

Inspections

Inspection Outcome Requested Scheduled Date Complete
Plumbing Rough-in Inspection Passed 8/4/2017 (8:00 - 10:00) 8/4/2017 08/04/2017
Corrections:


Miscellaneous/Other
Comment Only
08/04/2017
Add pipe fix to 1/2 " copper lines above wall near gas main. 2" vent exceeds horizontal length limit my approx. 15 ft. Calculate more closely on future jobs. Airtest 30/60 P.S.I. onIn- wall gas pipe approved. 5 P.S.I. Airtest on waste and vent in wall and above approved. Unsure of under floor piping. O.k. To cover all.

Plumbing Rough-in Inspection Passed 9/5/2017 (10:00 - 12:00) 9/5/2017 09/06/2017
Plumbing Final Inspection Not Ready 9/18/2017 (10:00 - 12:00) 9/18/2017 09/18/2017
Plumbing Final Inspection Passed 9/19/2017 (12:30 - 2:30) 9/19/2017 09/20/2017