Inspection | Outcome | Requested | Scheduled | Date Complete |
---|---|---|---|---|
Plumbing Rough-in Inspection | Partial Pass | 6/24/2019 (2:30 - 3:30) | 6/24/2019 (PM) | 06/24/2019 |
Corrections:
Miscellaneous/Other
Comment Only
06/24/2019
Air test on 180 feet for elevator pit drain.
Buried, saw photo
|
||||
Plumbing Rough-in Inspection | Partial Pass | 6/25/2019 (2:30 - 3:30) | 6/25/2019 (PM) | 06/25/2019 |
Corrections:
Miscellaneous/Other
Comment Only
06/25/2019
189 feet of pipe laid. Buried, unable to inspect. Finish elevator sump drain, put on Airtest and call for inspection.
|
||||
Plumbing Rough-in Inspection | Not Ready | 6/26/2019 (2:30 - 3:30) | 6/26/2019 (PM) | 06/26/2019 |
Plumbing Rough-in Inspection | Not Ready | 6/27/2019 (2:30 - 3:30) | 6/27/2019 (PM) | 06/27/2019 |
Corrections:
Miscellaneous/Other
Comment Only
06/27/2019
Rained out
|
||||
Plumbing Rough-in Inspection | Partial Pass | 9/16/2019 (10:00 - 12:00) | 9/16/2019 (AM) | 09/16/2019 |
Corrections:
Miscellaneous/Other
Comment Only
09/16/2019
Air test on under ground for break room sink
|
||||
Plumbing Rough-in Inspection | Partial Pass | 9/19/2019 (8:00 - 10:00) | 9/19/2019 (AM) | 09/19/2019 |
Corrections:
Miscellaneous/Other
Comment Only
09/19/2019
Rough in air test on under ground for bathrooms, ok to backfill
|
||||
Plumbing Rough-in Inspection | Partial Pass | 10/7/2019 (12:30 - 2:30) | 10/7/2019 (PM) | 10/07/2019 |
Plumbing Rough-in Inspection | Partial Pass | 10/8/2019 (12:30 - 2:30) | 10/8/2019 (PM) | 10/08/2019 |
Plumbing Rough-in Inspection | Partial Pass | 10/9/2019 (12:30 - 2:30) | 10/9/2019 (PM) | 10/09/2019 |
Plumbing Rough-in Inspection | Not Ready | 10/10/2019 (12:30 - 2:30) | 10/10/2019 (PM) | 10/10/2019 |
Plumbing Rough-in Inspection | Partial Pass | 10/14/2019 (12:30 - 2:30) | 10/14/2019 (PM) | 10/14/2019 |
Corrections:
Miscellaneous/Other
Comment Only
10/14/2019
Air test on under ground storm
|
||||
Plumbing Rough-in Inspection | Partial Pass | 10/15/2019 (12:30 - 2:30) | 10/15/2019 (PM) | 10/15/2019 |
Plumbing Rough-in Inspection | Partial Pass | 10/16/2019 (12:30 - 2:30) | 10/16/2019 (PM) | 10/16/2019 |
Corrections:
Miscellaneous/Other
Comment Only
10/16/2019
Ugat
|
||||
Plumbing Rough-in Inspection | Partial Pass | 10/17/2019 (12:30 - 2:30) | 10/17/2019 (PM) | 10/17/2019 |
Plumbing Rough-in Inspection | Partial Pass | 12/9/2019 (12:30 - 2:30) | 12/9/2019 (PM) | 12/09/2019 |
Corrections:
Miscellaneous/Other
Comment Only
12/09/2019
West side of building air tested.
|
||||
Plumbing Rough-in Inspection | Partial Pass | 12/10/2019 (10:00 - 12:00) | 12/10/2019 (AM) | 12/10/2019 |
Corrections:
Miscellaneous/Other
Comment Only
12/10/2019
Air test on 2 roof drain rain leaders
|
||||
Plumbing Rough-in Inspection | Partial Pass | 12/18/2019 (12:30 - 2:30) | 12/18/2019 (PM) | 12/18/2019 |
Corrections:
Miscellaneous/Other
Comment Only
12/18/2019
Airtest on 4 roof drains
And upper level bathroom
|
||||
Plumbing Rough-in Inspection | Partial Pass | 12/27/2019 (12:30 - 2:30) | 12/27/2019 (PM) | 12/27/2019 |
Corrections:
Miscellaneous/Other
Comment Only
12/27/2019
Air test on 4 rain leaders on the east side
|
||||
Plumbing Rough-in Inspection | Passed | 1/14/2020 (12:30 - 2:30) | 1/14/2020 (PM) | 01/14/2020 |
Corrections:
Miscellaneous/Other
Comment Only
01/14/2020
Air test on 3 over flows and 4 bathrooms
|
||||
Plumbing Final Inspection | Partial Pass | 3/2/2020 (10:00 - 12:00) | 3/2/2020 (AM) | 03/02/2020 |
Corrections:
Miscellaneous/Other
Comment Only
03/02/2020
Manometer tests on 2 bathrooms
|
||||
Plumbing Final Inspection | Passed | 3/26/2020 (10:00 - 12:00) | 3/26/2020 (AM) | 03/26/2020 |