PRPL202101075
There are no deposits or bonds for this permit application.
Inspection | Outcome | Requested | Scheduled | Date Complete |
---|---|---|---|---|
Plumbing Rough-in Inspection | Partial Pass | 3/2/2021 (12:30 - 2:30) | 3/2/2021 (PM) | 03/02/2021 |
Corrections:
Miscellaneous/Other
Comment Only
03/02/2021
Air test on underground ok to cover
2nd rough-in inspection air test on venting required
|
||||
Plumbing Rough-in Inspection | Partial Pass | 3/15/2021 (2:30 - 3:30) | 3/15/2021 (PM) | 03/15/2021 |
3/12/21 Contractor called to move this from 3/16/21 to 3/15/21. jms | ||||
Corrections:
Miscellaneous/Other
Comment Only
03/15/2021
Visual inspection on above ground plumbing.
No air test provided. Wafer missing. Why not get another one? Air tests are code required.
|
||||
Miscellaneous/Other
Comment Only
03/15/2021
Visual inspection on above ground plumbing.
No air test provided. Please call for re-inspection.
Air tests are code required.
|
||||
Plumbing Rough-in Inspection | Passed | 3/18/2021 (10:00 - 12:00) | 3/18/2021 (AM) | 03/18/2021 |
Plumbing Final Inspection | Partial Pass | 6/2/2021 | 6/2/2021 (AM) | 06/02/2021 |
Corrections:
Miscellaneous/Other
Comment Only
06/02/2021
Manometer test ok
One trap on 3 comp sink
Condensate on ovens
Flush valve on toilet
Seal toilet
Seal hand sink
Seal mop sink
Plumb rinse sink
Finish gas piping for ovens
Finish gas piping for water heaters
Valve and trap ice bin
|
||||
Plumbing Final Inspection | Passed | 6/8/2021 (12:30 - 2:30) | 6/8/2021 (PM) | 06/08/2021 |
Corrections:
Miscellaneous/Other
Comment Only
06/08/2021
Manometer test
|