Inspection | Outcome | Requested | Scheduled | Date Complete |
---|---|---|---|---|
Plumbing Rough-in Inspection | Passed | 8/18/2021 (8:00 - 10:00) | 8/18/2021 (AM) | 08/18/2021 |
Corrections:
Miscellaneous/Other
Comment Only
08/18/2021
Air test on all
Fire caulk hole in floor for water line to trap primer. Cover copper.
|
||||
Plumbing Final Inspection | Passed | 9/30/2021 (10:00 - 12:00) | 9/30/2021 (AM) | 09/30/2021 |
Corrections:
Miscellaneous/Other
Comment Only
09/30/2021
Manometer test
|