Inspection | Outcome | Requested | Scheduled | Date Complete |
---|---|---|---|---|
Plumbing Rough-in Inspection | Passed | 6/16/2022 (12:30 - 2:30) | 6/16/2022 (PM) | 06/16/2022 |
Corrections:
Miscellaneous/Other
Comment Only
06/16/2022
5 lb. Air test on waste and vent good.
|
||||
Plumbing Final Inspection | Partial Pass | 9/1/2022 (8:00 - 10:00) | 9/1/2022 (AM) | 09/01/2022 |
Corrections:
Miscellaneous/Other
Comment Only
09/01/2022
Partial final. Visual inspection on 2 new sinks, 2 instantaneous water heaters, and dishwasher. Discussed relocating bottle filler chiller to below return air plenum ceiling.
|
||||
Plumbing Final Inspection | Passed | 10/13/2022 (10:00 - 12:00) | 10/13/2022 (AM) | 10/13/2022 |
Corrections:
Miscellaneous/Other
Comment Only
10/13/2022
Changed plastic tubing for water chiller to soft copper in return air plenum. Will add access panel for water chiller discharge into standpipe.
|