Property Review

Parcel ID: 0402724130052


Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Property Details

0402724130052
Active
CONTROL DATA ADDITION Lot: 1 Block: CONTROL DATA ADDITION

Addresses

Street # Pre-Direction Street Name Direction Unit # Status
8001 BLOOMINGTON FWY Active

Contacts

Type Description
Property Owner 2510 BOATMAN LLC ET AL, Address:530 B ST #2050
Historic Owner GNMN001 LLC, Address:125 S WACKER DR #1220
Historic Owner GNMN002 LLC, Address:100 S 5TH ST #1075
Historic Owner GNMN002 LLC, Address:8001 BLOOMINGTON FWY

Zone (SINGLE FAMILY RESIDENTIAL (R-1))

SINGLE FAMILY RESIDENTIAL (R-1)
Active

Zone (GENERAL INDUSTRIAL (I-3))

GENERAL INDUSTRIAL (I-3)
Active

Permit Applications

Application Number Type Work Class Status Date Issued
PREL202410733 Electrical Alteration/Repair/Replace Finaled 08/19/2024
: Electrical

: INSTALL 4- 20 AMP 208V SINGLE PHASE DROP CORDS IN ENGINEERING LAB AND BTE REPAIR AREA. INSTALL 2- 30 AMP 208V 3-PHASE DROP CORDS IN SAME.
PREL202407776 Electrical Alteration/Repair/Replace Finaled 06/17/2024
: Electrical

: CONNECT FIRE SECURITY PANEL.
PRROWU202405450 ROW Underground N/A Finaled 05/03/2024
: Right-of-Way

: REPLACING/RELOCATING 3PHASE 1/0AL CABLE FROM CUSTOMER TRANSFORMER AT 82 1/2 ST W TO XCEL LBC CABINET 360' NORTH OF 80 1/2 ST W. JOB IS TO ACCOMMODATE MNDOT PROJECT - REALIGNING E BLOOMINGTON FWY
PREL202403793 Electrical Alteration/Repair/Replace Finaled 04/02/2024
: Electrical

: INSTALL 8- 20 AMP ISO GROUND 4-PLEX CORD DROP RECEPTACLES ON 8- DEDICATED CIRCUITS.
PREL202403437 Electrical Alteration/Repair/Replace Finaled 03/25/2024
: Electrical

: We are replacing the existing Bosch 9412 fire/burg panel with a DMP XR550 panel with cellular communicator. We will be reconnecting existing fire/sprinkler points to new panel.
PRAL202403436 Fire Alarm Alteration/Repair/Replace Finaled 04/02/2024
: Fire Alarm

: We are replacing the existing Bosch 9412 fire/burg panel with a DMP XR550 panel with cellular communicator. We will be reconnecting existing fire/sprinkler points to new panel.
PREL202315430 Electrical Alteration/Repair/Replace Finaled 12/21/2023
: Electrical

: WIRE AND MOUNT OWNER PROVIDED SPEED DRIVE FOR EXHAUST FAN. FEED FROM EXISTING 3-PHASE PANEL. INSTALL DISCONNECT PER CODE. WIRE ONLY 3-PHASE EXHAUST FAN. PROVIDE 120V POWER FOR DAMPER ACTUATOR MOTOR. FURNISH AND INSTALL RELAY TO INTERCONNECT DAMPER ACTUATOR WITH SPEED DRIVE.
PRROWU202313476 ROW Underground N/A Ready for Issuance
: Right-of-Way

: A new fiber network is being placed via Bore method in the ROW of the city. This permit is being sent on behalf of Intrepid Fiber by Troyer Group. The construction Contractor for this project is DirectLine Communications. The project associated with this permit is North OLT001 DA107 - REVISED City Buried C
PRROWU202313475 ROW Underground N/A Permit(s) Issued 11/06/2023
: Right-of-Way

: A new fiber network is being placed via Bore method in the ROW of the city. This permit is being sent on behalf of Intrepid Fiber by Troyer Group. The construction Contractor for this project is DirectLine Communications. The project associated with this permit is North OLT001 DA107 - REVISED City Buried B
PRROWU202313473 ROW Underground N/A Permit(s) Issued 11/06/2023
: Right-of-Way

: A new fiber network is being placed via Bore method in the ROW of the city. This permit is being sent on behalf of Intrepid Fiber by Troyer Group. The construction Contractor for this project is DirectLine Communications. The project associated with this permit is North OLT001 DA107 - REVISED City Buried A
PRROWU202307927 ROW Underground N/A Warranty 10/30/2023
: Right-of-Way

: A new fiber network is being placed via Bore method in the ROW of the city. This permit is being sent on behalf of Intrepid Fiber by Troyer Group. The construction Contractor for this project is slated to be DirectLine Communications. The project associated with this permit is Pilot: Sector 7 - City Buried A
PRMH202002242 Mechanical/HVAC Alteration/Repair/Replace Finaled 03/10/2020
: Mechanical

: RELOCATE THE EXISTING DIFFUSERS FROM THE EXISTING RTU ZONE TO SERVE THE 2-NEW OFFICE SPACES AND EXISTING AREA. GN Resound
PREL202002017 Electrical Alteration/Repair/Replace Finaled 03/04/2020
: Electrical

: Office Remodel
PRFS202001765 Fire Suppression System Alteration/Repair/Replace Expired 03/09/2020
: Fire Suppression System

: Off existing system Relocate (6) Add (2) sprinkler heads for new walls in remodel area. Existing heads are quick response chrome pendent any added heads to match. No change in density.
PRBD202000125 Building Alteration/Repair/Replace Finaled 02/10/2020
: Building

: Replacing lounge with two offices and hearing aid testing room. Fit and finish of marketing department adjacent to new offices.
PREL201914817 Electrical Other Finaled 12/12/2019
: Electrical

: Fire alarm adds (LV work) due to remodel. Adding (4) strobes in new private bathrooms, (1) in "mothers room" and horn/strobe in commons area.
PRAL201914815 Fire Alarm Other Finaled 12/16/2019
: Fire Alarm

: Fire Alarm adds due to remodel - add (4) strobes in new private bathrooms, (1) in "mothers room" and (1) in commons area.
PREL201913820 Electrical Alteration/Repair/Replace Finaled 11/14/2019
: Electrical

: BAth Remodel
PRMH201912634 Mechanical/HVAC Alteration/Repair/Replace Finaled 10/18/2019
: Mechanical

: RESTROOM HVAC PER PROPOSAL
PRPL201912086 Plumbing Alteration/Repair/Replace Finaled 10/15/2019
: Plumbing

: GN Resound Restrooms with Mothers room 6/16/2019 Job Description Receive permits and inspections as needed Demo and cap existing plumbing Mark floor for concrete work by other Install new waste, vent and water pipe as needed Install and supply fixtures for plumbing below 4 restrooms each consisting of One American Standard wall hung toilet with auto sensor flush valve One Delta single handle lav with mixing valve One American Standard Lucerne wall hung sink with grid strainer and trap wrap One set of ADA grab bars One 2 inch floor drain One set of ADA hi low drinking fountains with one bottle filler One SS drop in sink with 2 handle American Standard Colony faucet with goose neck spout One Bradford White 6 gallon water heater in ceiling as per meeting
PRFS201911919 Fire Suppression System Alteration/Repair/Replace Finaled 10/10/2019
: Fire Suppression System

: Relocate 6 existing sprinkler heads for restroom remodel. No change in density. Existing heads are quick response.
PRBD201910939 Building Alteration/Repair/Replace Finaled 10/07/2019
: Building

: Remove existing wood retaining wall and replace with modular block wall
PRBD201910504 Building Alteration/Repair/Replace Expired 10/30/2019
: Building

: Remove two gang toilet rooms with three fixtures each and replacing with four single user toilets plus a wellness room.
PRTC201905976 Tent/Canopy Other Finaled 06/12/2019
: Tent/Canopy

: Ultimate Events is hired to install a temporary 30' x 40' canopy for GN Resound. Ultimate Events will also provide tables and chairs for seating. Set: Wednesday, July 17th. Event: Thursday, July 18th at 11am. Strike: Friday, July 19th morning.
PRTC201903619 Tent/Canopy Other Finaled 04/19/2019
: Tent/Canopy

: West parking lot of 8001 E Bloomington Fwy. Tent set up 4/26/19. Tent removal after event 4/26/19. Serving food.
PREL201900047 Electrical Alteration/Repair/Replace Finaled 01/03/2019
: Electrical

: Installation of 2 new smoke detectors.
PRAL201900030 Fire Alarm Other Finaled 01/03/2019
: Fire Alarm

: Installation of 2 new smoke detectors by the new fire door and tie them to the door close/drop into the same ouotput as the other doors.
PRMH201814397 Mechanical/HVAC Alteration/Remodel Expired 11/26/2018
: Mechanical

: INSTALL (1) 4-TON RTU ON EXISTING ROOF CURB WITH DUCTWORK AND DIFFUSERS FOR A SPACE REMODEL.
PRFS201808501 Fire Suppression System Other Expired 08/02/2018
: Fire Suppression System

: Add/relocate/install (14) pendant sprinkler heads to conform to new wall/ceiling layout.
PREL201807624 Electrical Alteration/Remodel Finaled 07/19/2018
: Electrical

: Remodel for GN Resound.
PRTC201807259 Tent/Canopy Other Finaled 07/13/2018
: Tent/Canopy

: Tent set up 07/16/17; tent removal after event 07/17
PRBD201803194 Building Alteration/Remodel Expired 07/05/2018
: Building

: Construct salvage room, relocate training room, expand locker room.
PRFS201711392 Fire Suppression System Alteration/Remodel Finaled 12/06/2017
: Fire Suppression System

: Relocate/add (7) sprinkler heads for new wall/ceiling layout.
PRMH201711058 Mechanical/HVAC Alteration/Remodel Finaled 11/17/2017
: Mechanical

: Install 3-ton RTU with economizer and gas piping from existing roof piping system.
PRBD201711033 Building Alteration/Remodel Finaled 12/19/2017
: Building

: Construct 3 collaborative offices
PREL201710321 Electrical Alteration/Remodel Finaled 10/26/2017
: Electrical

: Office expansion
PRTC201705678 Tent/Canopy Other Finaled 07/06/2017
: Tent/Canopy

: Tent set up in West parking lot of 8001 E Bloomington Freeway
PREL201702879 Electrical Repair/Replace Finaled 04/26/2017
: Electrical

: exterior lighting improvements.


Planning Applications

Project Number Type Status Date Closed
PL202200255 Zoning Verification Requests File Closed
: GN ReSound (22-394981.2)
PL202200188 Zoning Verification Requests File Closed
: 8001 Bloomington Freeway Zoning Verification Letter
PL202000207 Zoning Verification Requests File Closed
: Zoning Letter
PL201800199 Development Application File Closed
: GN Resound FSBP