PRMH202501444
|
Mechanical/HVAC
|
Alteration/Repair/Replace
|
Permit(s) Issued
|
02/25/2025
|
|
:
Mechanical
:
• Replace the existing cooling tower with new Evapco AT cooling tower
• Including 20HP tower fan motor, 14kw heater, electrical NEMA 4 panel with contactor, transformer and disconnect
• Install customer provided basin sweeper pump on roof next to tower and connect to high eduction sump sweeper piping in tower, including power wiring to panel located in mechanical room below
• Provide and install cottonwood screen for cooling tower
• New ladder to be mounted to the side of the tower for servicing
• Disconnect and reconnect existing PVC water supply and return piping
• Disconnect and reconnect existing power wiring
Embassy Suites Mpls Airport - Uhl Job 024SP020
|
PREL202411464
|
Electrical
|
Other
|
Expired
|
09/04/2024
|
|
:
Electrical
:
EST3-EST4 upgrade. Replace room smokes to smoke/co detectors. Upgrade bases to 520hz bases.
|
PRAL202411463
|
Fire Alarm
|
Other
|
Finaled
|
09/12/2024
|
|
:
Fire Alarm
:
EST3-EST4 upgrade. Replace room smokes to smoke/co detectors. Upgrade bases to 520hz bases.
|
PRROWO202411064
|
ROW Obstruction
|
N/A
|
Finaled
|
09/13/2024
|
|
:
Right-of-Way
:
Track repairs at south diverging diamond of 34th Avenue and 494.
Track repair at 75th Ave at intersection of railroad crossing.
|
PRROWU202408728
|
ROW Underground
|
N/A
|
Warranty
|
09/09/2024
|
|
:
Right-of-Way
:
P.239170 (1 of 1)
Bore 135' to place a new 1.25" conduit with fiber cable, from an existing manhole in the boulevard area at 3700 American Blvd E. to a new proposed handhole to be installed in the boulevard at 7901 34th Ave S. All work is along the north side of American Blvd E.
|
PREL202315309
|
Electrical
|
Alteration/Repair/Replace
|
Finaled
|
12/20/2023
|
|
:
Electrical
:
Pool Pak HVAC replacement. Reconnect new Pool Pak air handler and condensing unit.
|
PRFS202314741
|
Fire Suppression System
|
Alteration/Repair/Replace
|
Finaled
|
12/06/2023
|
|
:
Fire Suppression System
:
Add one sprinkler and relocate one sprinkler to conform to modifications made in mechanical room.
|
PRMH202312684
|
Mechanical/HVAC
|
Alteration/Repair/Replace
|
Expired
|
11/14/2023
|
|
:
Mechanical
:
Replace Pool dehumidification unit - Embassy Suites Uhl 023SP039
|
PRBD202311966
|
Building
|
Alteration/Repair/Replace
|
Finaled
|
10/05/2023
|
|
:
Building
:
Enlarging 1 room - eliminating 2 walls
|
PRPL202306407
|
Plumbing
|
Alteration/Repair/Replace
|
Finaled
|
06/20/2023
|
|
:
Plumbing
:
Replace new RPZ in pool room.
|
PREL202304575
|
Electrical
|
Other
|
Expired
|
05/08/2023
|
|
:
Electrical
:
INSTALLATION OF 100AMP SERVICE 240/480 W/5 CKTS FOR MN DOT STREET LIGHTING IN THE SW CORNER OF 34TH AVENUE AND I-494 EB RAMP - SEE ATTACHED PLAN FOR LOCATION
EGAN # 359147 DAN BACHLER IS THE FIELD CONTAC- 612-298-9747
|
PRMH202101098
|
Mechanical/HVAC
|
Alteration/Repair/Replace
|
Expired
|
02/08/2021
|
|
:
Mechanical
:
Run a new gas line to kitchen.
|
PRTC202005457
|
Tent/Canopy
|
Other
|
Finaled
|
06/16/2020
|
|
:
Tent/Canopy
:
20x30 Ft Tent in parking lot. Tent is being used for outdoor pation seating during Phase 2 of COVID 19 reopening.
|
PRROWU202002117
|
ROW Underground
|
N/A
|
Finaled
|
02/14/2022
|
|
:
Right-of-Way
:
Installing New Small Cell Pole/Foundation/Equipment, and related electrical meter and conduit.
|
PREL202001952
|
Electrical
|
Alteration/Repair/Replace
|
Expired
|
03/04/2020
|
|
:
Electrical
:
Temp Control Wiring - DDC Controls
Embassy Suites Chiller Replace - Uhl Job 020ST004
|
PRROWS202001225
|
ROW Small Cell
|
N/A
|
Finaled
|
02/10/2020
|
|
:
Right-of-Way
:
New small cell on Xcel owned pole. Permit issued in 2019.
|
PRMH202000710
|
Mechanical/HVAC
|
Alteration/Repair/Replace
|
Finaled
|
02/03/2020
|
|
:
Mechanical
:
Remove and install one (1) 300 ton chiller.
Embassy Suites Bloomington - Uhl Job 020ST004
|
PREL201911387
|
Electrical
|
Other
|
Finaled
|
09/30/2019
|
|
:
Electrical
:
Embassy Suites Melink Labor to install customer-provided parts.
|
PRMH201908763
|
Mechanical/HVAC
|
Alteration/Repair/Replace
|
Expired
|
08/05/2019
|
|
:
Mechanical
:
- Reclaim system and dispose of refrigerant and unit properly.
- Install new Bryant 5- ton A410 Condensing unit, Air handler and line set.
- Pressure test system and pull vacuum.
- Open system and check operating pressures and amp draw.
- Document results and leave paperwork on site.
- ELECTRICAL WORK BY OTHERS.
|
PRMH201908762
|
Mechanical/HVAC
|
Alteration/Repair/Replace
|
Expired
|
08/05/2019
|
|
:
Mechanical
:
- Reclaim system and dispose of refrigerant and unit properly.
- Install new Bryant 3 ton A410 Condensing unit, Air Handler, Electric Heater
Element and line set.
- Pressure test system and pull vacuum.
- Open system and check operating pressures and amp draw.
- Document results and leave paperwork on site.
- ELECTRICAL WORK BY OTHERS.
|
PREL201908267
|
Electrical
|
Alteration/Repair/Replace
|
Expired
|
07/24/2019
|
|
:
Electrical
:
Extending Fire Alarm circuits for ADA compliance of rooms.
Pair with PRFA201907775
|
PRAL201907775
|
Fire Alarm
|
Alteration/Repair/Replace
|
Finaled
|
07/18/2019
|
|
:
Fire Alarm
:
Fire Alarm Modifications & Additions for ADA compliance
|
PRMH201904992
|
Mechanical/HVAC
|
Alteration/Repair/Replace
|
Finaled
|
05/21/2019
|
|
:
Mechanical
:
Remove and replace 140 existing first CO fan coil units with exact replacements by First CO. Continuation of work permitted under PRMH201900042.
|
PREL201904004
|
Electrical
|
Alteration/Repair/Replace
|
Finaled
|
04/29/2019
|
|
:
Electrical
:
Remodeling 3rd floor guest rooms.
|
PRFS201903842
|
Fire Suppression System
|
Alteration/Repair/Replace
|
Finaled
|
04/26/2019
|
|
:
Fire Suppression System
:
In each of the following suites, extend 2 heads relocate 1 head due to remodel for ADA compliance: 222,315,332,415,532,515,532,615,715,815,915,1015,513 and 415
|
PREL201903371
|
Electrical
|
Alteration/Repair/Replace
|
Finaled
|
04/18/2019
|
|
:
Electrical
:
4th Floor guest room remodeling
|
PREL201903183
|
Electrical
|
Alteration/Repair/Replace
|
Finaled
|
04/15/2019
|
|
:
Electrical
:
5th floor Guest rooms are remodeled
|
PREL201902270
|
Electrical
|
Alteration/Repair/Replace
|
Finaled
|
03/21/2019
|
|
:
Electrical
:
Remodeling guest rooms on 6th floor
|
PREL201902045
|
Electrical
|
Alteration/Repair/Replace
|
Finaled
|
03/12/2019
|
|
:
Electrical
:
REMODELING 7TH FLOOR
|
PREL201901393
|
Electrical
|
Alteration/Repair/Replace
|
Finaled
|
02/19/2019
|
|
:
Electrical
:
Remodeling of the 8th floor rooms. Embassy Suites
|
PRPL201901338
|
Plumbing
|
Alteration/Repair/Replace
|
Finaled
|
02/14/2019
|
|
:
Plumbing
:
Remove (2) Ray Pak commercial water heaters and replace with (2) RBT heaters.(paper application)
|
PREL201901319
|
Electrical
|
Alteration/Repair/Replace
|
Finaled
|
02/22/2019
|
|
:
Electrical
:
HOOK UP PERMANENT POWER TO DOMESTIC HOT WATER BOILERS.
|
PREL201901064
|
Electrical
|
Alteration/Repair/Replace
|
Finaled
|
02/04/2019
|
|
:
Electrical
:
Remodeling of 9th floor rooms. Embassy Suites by Hilton.
|
PREL201900949
|
Electrical
|
Alteration/Repair/Replace
|
Finaled
|
01/30/2019
|
|
:
Electrical
:
Wire room HVAC units. Embassy Suites.
|
PRPL201900859
|
Plumbing
|
Alteration/Repair/Replace
|
Finaled
|
01/30/2019
|
|
:
Plumbing
:
Replace fixtures in Embassy Suites hotel
|
PREL201815554
|
Electrical
|
Alteration/Repair/Replace
|
Finaled
|
01/04/2019
|
|
:
Electrical
:
Remodeling of existing hotel rooms. 10th floor
|
PREL201815044
|
Electrical
|
Alteration/Repair/Replace
|
Finaled
|
12/12/2018
|
|
:
Electrical
:
Remodel Hotel rooms on 2nd floor of hotel
|
PRPS201813971
|
Sign, Permanent
|
Face Change
|
Finaled
|
11/26/2018
|
|
:
Sign
:
Reface Projecting Sign
|
PREL201813413
|
Electrical
|
Repair/Replace
|
Finaled
|
10/26/2018
|
|
:
Electrical
:
paper application:
Doublehood in kitchen with double piranha system. Muska #C78228
|
PREHP201812310
|
Environmental Health Plan
|
Alteration/Remodel
|
Finaled
|
10/12/2018
|
|
:
Environmental Health Plan
:
Remodel bar area. (Woolley's Restaurant/Embassy Suites)
|
PRFS201811934
|
Fire Suppression System
|
Other
|
Finaled
|
10/09/2018
|
|
:
Fire Suppression System
:
Remove existing sprinkler. Install new ansul piranha systems.
|
PRDR201810880
|
Driveway
|
Repair/Replace
|
Finaled
|
09/18/2018
|
|
:
Driveway
:
Replace Concrete Apron off American Blvd E north of 34th Ave intersection. Also (at a later date) replace concrete apron off 34th ave south just west of American blvd E
|
PRAL201809118
|
Fire Alarm
|
Alteration/Remodel
|
Finaled
|
08/17/2018
|
|
:
Fire Alarm
:
RELOCATE FIRE ALARM DEVICES
(1)-SPEAKER STROBE
(4)-FIRE ALARM JUNCTION BOX
(1)-NAC POWER SUPPLY
|
PREL201809116
|
Electrical
|
Alteration/Remodel
|
Expired
|
08/15/2018
|
|
:
Electrical
:
RELOCATE FIRE ALARM DEVICES
(1)-SPEAKER STROBE
(4)-F/A JUNCTION BOX
(1)-NAC POWER SUPPLY
|
PRFS201808073
|
Fire Suppression System
|
Other
|
Finaled
|
08/15/2018
|
|
:
Fire Suppression System
:
Hook up pre-piped hood with ansul/piranha system
|
PRUT201807746
|
Utility
|
New
|
Finaled
|
07/19/2018
|
|
:
Utility
:
8 storm manhole/catchbasins, 3 storm alts, 1 - 12x6 water tap, 4 water alts, 1 fire hyd
|
PRMH201807700
|
Mechanical/HVAC
|
Alteration/Remodel
|
Finaled
|
07/23/2018
|
|
:
Mechanical
:
Modify supply diffusers. ( plans attached)
|
PREL201807633
|
Electrical
|
Other
|
Finaled
|
07/27/2018
|
|
:
Electrical
:
Install 24 light poles and concrete bases by boring and stitching underground.
|
PRFS201807482
|
Fire Suppression System
|
Repair/Replace
|
Finaled
|
07/18/2018
|
|
:
Fire Suppression System
:
Add/relocate sprinkler heads to new floor plan to meet NFPA 13 2010 requirements.
|
PRMH201807044
|
Mechanical/HVAC
|
Repair/Replace
|
Finaled
|
07/09/2018
|
|
:
Mechanical
:
make pool heater room non-plenum wrap pool heater. Piping located in plenum ceiling with FyerWrap. Install one floor drain.
|
PRUT201806264
|
Utility
|
New
|
Finaled
|
06/22/2018
|
|
:
Utility
:
Installation of Grease Interceptor - 5 san manholes, 4 sewer alterations
|
PRPL201805907
|
Plumbing
|
Alteration/Remodel
|
Finaled
|
06/14/2018
|
|
:
Plumbing
:
Install new bar and kitchen equipment per engineered plans.
|
PREL201805797
|
Electrical
|
Repair/Replace
|
Finaled
|
06/20/2018
|
|
:
Electrical
:
furnish and install 79 fixtures, 5 j-boxes, 4 switches, occupancy sensors, 15 dimmers, 1 time clock, 20 receptacles, 4 tv openings, 8 phone/data openings, 2 breakers, panel E, relamp 39 fixtures, wire kitchen equipment and condensate pump.
|
PREHP201805772
|
Environmental Health Plan
|
Alteration/Remodel
|
Ready for Issuance
|
|
|
:
Environmental Health Plan
:
This project consists of the renovation of 310 guest rooms as well as the public corridors, railings, stairs and various support staff spaces, all comprised on floors two through ten. No exterior envelope or landscape work will be performed. Exit stairs will remain open during construction to facilitate egress.
No construction will take place on the ground floor unless required for plumbing or electrical connections from above. The existing HVAC system will remain untouched except for 12 rooms being modified for ADA use. Twelve rooms will be converted into fully accessible guest rooms, four with showers and eight with tubs. Each guest room will receive light fixture replacements and minor modifications to existing outlets and switches. Interior finishes and new paint will be replaced throughout.
|
PRBD201805687
|
Building
|
Alteration/Remodel
|
Expired
|
12/12/2018
|
|
:
Building
:
This project consists of the renovation of 310 guest rooms as well as the public corridors, railings, stairs and various support staff spaces, all comprised on floors two through ten. No exterior envelope or landscape work will be performed. Exit stairs will remain open during construction to facilitate egress. No construction will take place on the ground floor unless required for plumbing or electrical connections from above.
|
PRBD201804269
|
Building
|
Alteration/Remodel
|
Finaled
|
06/14/2018
|
|
:
Building
:
Demo & Remodel of Woolley's Bar in the Embassy Suites
|
PRFS201803318
|
Fire Suppression System
|
Other
|
Finaled
|
04/17/2018
|
|
:
Fire Suppression System
:
Remove and replace appx 20 pendant heads with (1) piece plates to new simi recessed due to new ceiling in kitchen area.
|
PRBD201803216
|
Building
|
Alteration/Repair/Replace
|
Closed
|
01/14/2019
|
|
:
Building
:
Replace ceiling grid. White galvanized steel grid with vinyl coated fire rock.
|
PRPK201800968
|
Parking Lot
|
New
|
Finaled
|
07/12/2018
|
|
:
Parking Lot
:
Parking lot site development of a vacant lot and repave existing lot. New light poles and replace existing, install landscaping per plan. Embassy Suites
|
PRFS201800188
|
Fire Suppression System
|
Other
|
Finaled
|
01/09/2018
|
|
:
Fire Suppression System
:
Add/relocate fire sprinkler heads for main floor remodel. 1 for 1 relocates.
|
PRST201711841
|
Structural
|
Alteration/Remodel
|
Finaled
|
12/15/2017
|
|
:
Building
:
Structural permit for Embassy Suites Hotel. Install concrete piers and footings for walls and posts. Install trenches for underground waste, water, and electrical. Install concrete for raised platform in atrium. Separate building permit will be issued as well.
|
PRMH201711699
|
Mechanical/HVAC
|
Alteration/Remodel
|
Finaled
|
01/03/2018
|
|
:
Mechanical
:
Embassy Suites mechanical and hvac in cook-to-order area, pool area, fitness room, lobby/luggage area (based on attached scope of work). Only HVAC work (excludes gas piping, power wiring, engineering, structural work, roofing orf equipment screening, fire suppression). Applicant only had "see plans" in description of work.
|
PRDE201711095
|
Demolition
|
Alteration/Remodel
|
Expired
|
11/16/2017
|
|
:
Demolition
:
Selective demolition of public spaces.
|
PRPL201710741
|
Plumbing
|
Alteration/Remodel
|
Finaled
|
05/10/2018
|
|
:
Plumbing
:
Remodel of existing mens and womens restrooms in Atrium. Remodel of existing mens and womens pool area restrooms. Remodel of existing cook to order kitchen in Atrium. Gas hook up for 2 griddles and one stove to existing gas line/cook line.
|
PREL201710520
|
Electrical
|
Alteration/Remodel
|
Finaled
|
11/01/2017
|
|
:
Electrical
:
Remodel of main floor lobby and Atrium. Embassy Suites Hotel.
|
PREL201710456
|
Electrical
|
Alteration/Remodel
|
Permit(s) Issued
|
10/31/2017
|
|
:
Electrical
:
Installation of Building Automation Systems (BAS). Embassy Suites.
|
PREHP201710299
|
Environmental Health Plan
|
New
|
Finaled
|
05/30/2018
|
|
:
Environmental Health Plan
:
Alterations at cook to order kitchen, trash room and pool.
|
PRBD201709422
|
Building
|
Alteration/Remodel
|
Finaled
|
03/14/2018
|
|
:
Building
:
Interior renovation of the atrium and 1st floor public spaces.
|
PRMH201705480
|
Mechanical/HVAC
|
Repair/Replace
|
Finaled
|
07/06/2017
|
|
:
Mechanical
:
Replace existing MUA in penthouse at Embassy Suites with new Trane 2525 MBTU/hr 53,000 CFM; Modify existing piping to allow simultaneous heating and cooling.
|
PRMH201704306
|
Mechanical/HVAC
|
Repair/Replace
|
Finaled
|
06/01/2017
|
|
:
Mechanical
:
Replace existing AHU serving laundry room with new.
|
PREL201704161
|
Electrical
|
Alteration/Remodel
|
Permit(s) Issued
|
06/01/2017
|
|
:
Electrical
:
Smoke detector additions for for storage rooms.
|
PRAL201704160
|
Fire Alarm
|
Alteration/Remodel
|
Permit(s) Issued
|
06/01/2017
|
|
:
Fire Alarm
:
Addition of (18) smoke detectors for storage rooms.
|
PRCRF201700397
|
Roof, Commercial
|
Repair/Replace
|
Finaled
|
02/22/2017
|
|
:
Roofing
:
|